4 Software Operation
MIX 56 User Manual
4-32
Telect, Inc. 122188-10 A0
c. On pressing y and Enter the file with the base name as spec-
ified on screen 10 and with the extension of “.nvr” is re-
trieved from the TFTP file server.
NOTES
- The file must have been previously saved via one of the save
file options of the Save Configuration screen.
- Restoring the NVRam from a file results in a reboot of the
Mix56 card.
V
IEWING
E
RRORS
Viewing High-Speed Errors
You can view DS3 error counts in either of the following ways:
•
15-Minute Histories—Error count totals are displayed for every 15-
minute period in the last 24 hours (96 periods total), including the cur-
rent period.
•
24-Hour Histories—Error count totals are displayed for two time peri-
ods: from Midnight the current day to the end of the last completed 15-
minute period and from midnight the previous day to one second before
Midnight of the current day.
Error Definitions
These definitions are per ANSI T1.231. You can view all of the following
DS3 errors in either of the displays described above.
Errored Seconds (ES):
A second with one or more bipolar violations
(BPV), excessive zeros (EXZ), or loss of signal (LOS).
Severely Errored Seconds (SES):
A second in which 45 or more BPVs,
EXZs, or LOS’ occur.
Coding Violations (CV):
A cumulative count of BPVs and/or EXZs for
the period of time displayed.
Loss of Signal Seconds (LOSS):
A second containing one or more LOS
detects.
Alarm Indication Signal Seconds (AISS):
A second in which an Alarm
Indication Signal (AIS) is received.
Failure Count (FC):
A cumulative count of loss of frame (LOF) and/or
AIS seconds (until the counts are cleared).
Содержание MIX 56
Страница 1: ... MIX 56 122188 10 A0 USER MANUAL ...
Страница 6: ...vi Telect Inc 122188 10 A0 ...
Страница 10: ...x Telect Inc 122188 10 A0 ...
Страница 100: ...4 Software Operation MIX 56 User Manual 4 54 Telect Inc 122188 10 A0 ...
Страница 116: ...5 Owner Maintenance MIX 56 User Manual 5 16 Telect Inc 122188 10 A0 ...
Страница 123: ......