SHDSL Configuration:
=======================================================
Active: yes
Lines: 1,2,3,4
Masterline: 1
CO/CPE: CPE
TC Layer: EFM
Ext. rates: Enabled
Lineprobing: Enabled
Bitrate min: 64 kbps
Bitrate max: 15336 kbps
PAM: Auto
Annex: ANNEX_B
SNRM: 6 dB
=======================================================
SDFE download ... ok.
IDC download ... ok.
IDC start ... ok.
Line #1 Line #2 Line #3 Line #4
Linestate: DOWN_NOT_READY DOWN_NOT_READY DOWN_NOT_READY DOWN_NOT_READY
Mode: STU-R (CPE) STU-R (CPE) STU-R (CPE) STU-R (CPE)
Bitrate/PAM:
SNRM/LATN(NE):
SNRM/LATN(FE):
0======================================================
If the hardware configuration is changed (e.g. new switch position of rotary switch) you get a
confirmation print out like that:
HW Config changed (dip:0x01, rot:1)
SHDSL config activate successful
During operation you get a cyclic status print out like that:
Line #1 Line #2 Line #3 Line #4
Linestate: UP_DATA_MODE UP_DATA_MODE UP_DATA_MODE UP_DATA_MODE
Mode: STU-C (CO) STU-C (CO) STU-C (CO) STU-C (CO)
Bitrate/PAM: 192 kbps/16-TCPAM 192 kbps/16-TCPAM 192 kbps/16-TCPAM 192 kbps/16-TCPAM
SNRM/LATN(NE): 29 dB/ 1 dB 28 dB/ 1 dB 29 dB/ 1 dB 28 dB/ 1 dB
SNRM/LATN(FE): 28 dB/ 1 dB 27 dB/ 1 dB 26 dB/ 1 dB 27 dB/ 1 dB
==========================================0============
If you press the “ERASE” button, you will get a summary of state information. It looks like this:
#######################################################
Boot-Ver#: 3.0-R2559
SW-Ver#: 3.0-R2569
PHY-Ver#: 1.1-2.1.0__001
IDC-Ver#: 2.1.0.0