UK
Anleitung Türstationen a / b Serie 20 / 40 / 50
Configurations and Set-up
GB
36
www.behnke-online.com
Code Parameter
Confirmation
00
Reset and restore default settings:
* * * *
#
01
Change security code:
Default: 0 0 0 0
new code [beep] new code
#
03
Answering the telephone call when the doorbell was rung:
Default: 1
0 = automatically with manual confirmation via DTMF signal 0-9
(cf. Configuration step 9910)
1 = automatically
#
#
05
Connection interval:
Default: 3
0 = unlimited (i.e. limited to approx. 8 hours)
1 = limited to 1 minute
…
9 = limited to 9 minutes
#
#
…
#
06
Volume:
Default: 3
1 = soft
…
5 = loud
#
…
#