![Tele Radio Tiger D8-1 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/tele-radio/tiger-d8-1/tiger-d8-1_installation-instructions-manual_1079614010.webp)
10
2.The signals and alarm + warnings flags are distributed over RS485/
MODBUS to the Tiger receiver.
3. Each receiver have 4 clusters for handling the signals. We recommend
selecting an empty cluster for each new input signal. E.g. cluster 1 for the
1st input signal, cluster 2 for the 2nd input signal, cluster 3 for the 3rd
input signal and cluster 4 for the 4th input signal.
An upper alarm limit, an upper warning limit, an upper hysteresis limit
+ a lower alarm limit, a lower warning limit, a lower hysteresis limit can
be set for each cluster. One or more relays can be activated or blocked
when the alarm limits and warning limits are reached. The feedback can be
displayed according to your needs.
4. The weight value is the output from each cluster: Weight 1 is the output
from cluster 1, weight 2 is the output from cluster 2 etc. If more than one
weight value is received in a cluster, the output from that cluster is the
sum of the incoming weight values.
5. The transmitter will act upon the input from the receiver, e.g. show a
message in the display or flash a LED. NOTE! You will need a bindat file in
the transmitter to receive feedback.