mOmENTaRy OR LaTChED RELay FuNCTiONS
The system is supplied with an momentary function as the default setting. Program as set out below if you want
a latched function.
Momentary function:
The relay only switches/activates during the period the button on the transmitter is pressed down.
Latched/Toggling function:
The position of the relay changes each time the button on the transmitter is pressed, but maintains its new
position once the button has been released.
Programming tHe LatCHeD reLay fUnCtion:
1. Start the system.
2. Turn the receiver’s function selector switch 1 to the ON position.
– All the relays in the receiver are disconnected and the red LEDs for respective relays go out.
3. Press the buttons on the transmitter that you wish to assign a latched/toggling function.
– The red LED will light continuously above respective relays that you have chosen to assign latched/toggling
functions.
4. Turn the receiver’s function selector switch 1 to the OFF position.
– Latched relay functions are programmed and can now be used.
retUrn to tHe DefaULt Setting (momentary):
1. Start the system.
2. Turn the receiver’s function selector switch 1 to the ON position.
– All the relays in the receiver are disconnected and the red LEDs for respective relays go out.
3. Turn the receiver’s function selector switch 1 to the OFF position.
– All relays have an momentary function.
iNTERLOCKS
Interlocking means it is possible to interlock/prioritise a relay function/button before another.
If interlocking has been programmed and two buttons on the transmitter are pressed simultaneously, one the
buttons is given priority/interlocked over the other, which means, for example, up and down movements cannot
be operated at the same time.
Look through and decide what options you want to program, by using the table below, before you start pro-
gramming.
Note that the option OFF OFF = no interlocking. (Example LED 1 = OFF and LED 2 = OFF.)
interlocks 10x1
red LeDs for resp. relays
Functions 1-2 are blocked when pressed simultaneously.
LED 1 = ON
LED 2 = ON
Functions 3-4 are blocked when pressed simultaneously.
LED 3 = ON
LED 4 = ON
Functions 5-6 are blocked when pressed simultaneously.
LED 5 = ON
LED 6 = ON
Functions 7-8 are blocked when pressed simultaneously.
LED 7 = ON
LED 8 = ON
Functions 9-10 are blocked when pressed simultaneously.
LED 9 = ON
LED 10 = ON
interlocks 10x/1x
red LeDs for resp relays
Function 11 has priority over 1, function 12 over 2.
LED 1 = ON
LED 2 = OFF
Function 11 has priority over 1, function 12 over 2. Function 1-2,
11-12 are blocked when pressed simultaneously.
LED 1 = OFF
LED 2 = ON
Function 1-2, 11-12 are blocked when pressed simultaneously.
LED 1 = ON
LED 2 = ON
Function 13 has priority over 3, function 14 over 4.
LED 3 = ON
LED 4 = OFF
Function 13 has priority over 3, function 14 over 4. Functions 3-4,
13-14 are blocked when pressed simultaneously.
LED 3 = OFF
LED 4 = ON