Fig. 24:
Inserting the SIM in the internal tray
4.4 RST Button
The Regesta Smart PRO has a button that can be accessed from the outside and is labeled “RST”. It is located on
the connector panel and has two functions.
• To trigger a reboot.
• To restart the device with the default configuration. The default configuration has IP 192.168.1.1 assigned to all
switch ports.
The external button is physically protected to stop it from being accidentally pushed. You need a sharp-pointed ob-
ject to activate it.
4.4.1 Restarting the device
Carry out the following steps to restart the device:
(1)
Press the RST button. The device restarts with the S,C and L LEDs in the
off
state and the ON LED lighting in
green.
(2)
Stop pressing the RST button as soon as the S, C and L LEDs switch to the
off
state.
(3)
The device will restart with LEDs S and C in the
off
state and LEDs L and ON in green.
4.4.2 Default Configuration
By following these steps, the RST button allows you to boot the device with its default configuration:
(1)
Press the RST button. The device restarts with the S,C and L LEDs in the
off
state and the ON LED lights up in
green.
(2)
Keep pressing the RST button while the S LED flashes in green and the L LED lights up in green. This indicates
the device configuration has changed to the default configuration.
(3)
Stop pressing the RST button to allow the device to restart.
(4)
The device will restart with LEDs S and C in the
off
state and LEDs L and ON in green.
(5)
As the device now has the default configuration, you can access it through the IP (bearing in mind that the de-
fault address for the equipment is 192.168.1.1 and that it is accessible from any switch port).
4.5 Troubleshooting
The following table can help you solve problems when installing the device. If you cannot solve the problem, contact
your dealer for more information.
Symptom
Solution
No LED lights up on the router.
Check the power supply to the router (power source, main power outlet).
The local console does not re-
spond.
Check the console cable is the right one and that it is connected to the device and
the asynchronous terminal.