background image

Fig. 4:

Connector Panel

The elements found in the connector panel are as follows:
Table 1: Front Panel Elements

Item

Description

A

RST. Reset button. For further information on how the reset button works, please see

RST

Button

on page 28.

B

CONF. RJ-45 connector providing access to the device's local console for configuration and
monitoring purposes. (This connector can also be used as an RS-232 asynchronous DCE
serial port.)

For more information about the CONF connector, refer to:

-

Console Connector as Serial Port (CONF connector)

on page 25

-

Configuration Connector

on page 35

-

Configuration Interface

on page 38

C

WAN Gigabit Ethernet. SFP connector.

For more information about the WAN interface with SFP connector, refer to:

-

WAN connections

on page 21

-

WAN SFP Connector

on page 34

-

WAN SFP Interface

on page 37

D

WAN Gigabit Ethernet. RJ-45 connector.

For more information about the WAN interface with Base-T connector, refer to:

-

WAN connections

on page 21

-

WAN Base-T Connector

on page 34

-

WAN Base-T Interface

on page 37

E

LAN Gigabit Ethernet Port.

2 Product Overview

Teldat S.A.

10

Regesta Smart PRO

Содержание Regesta Smart PRO

Страница 1: ...Regesta Smart PRO Installation Manual Copyright Teldat Dm1002 I Version 1 0 12 2019 Teldat S A Teldat S A Manual Regesta Smart PRO 1...

Страница 2: ...t S A offers no warranty whatsoever for information contained in this manual Teldat S A is not liable for any direct indirect collateral consequential or any other damage connected to the deliv ery su...

Страница 3: ...iption 5 2 2 Device Models 6 2 3 Hardware Features 7 2 4 Components 8 2 4 1 Front Panel 8 2 4 2 Connector Panel 9 2 4 3 Underside Panel 12 2 5 Power Supply 12 2 5 1 AC Power Supply 13 2 5 2 DC Power S...

Страница 4: ...nnecting to the router 29 Chapter 5 Compliance 31 5 1 Manufacturer Information 31 5 2 Intended use of the equipment 31 5 3 EC Declaration of Conformity No Radio version 31 5 4 EC Declaration of Confor...

Страница 5: ...5 WAN SFP Interface 37 A 2 6 Wireless WAN interface 38 A 2 7 Configuration Interface 38 A 2 8 RS 232 Serial Interface 38 A 2 9 RS 485 Serial Interface 38 A 2 10 Power Supply Specifications 39 A 2 11...

Страница 6: ...manual This installation manual contains the following information A description of the available features in the Regesta Smart PRO router Technical specifications Power supply requirements A descrip...

Страница 7: ...1 8 Safety Warnings DC powered device AC powered device 0 1 0 0 1 0 2345 0 144 4 67 2 8 9 1 0 4226 2345 0 144 0 4 67 2 8 9 1 0 4226 1 About This Manual Teldat S A 2 Regesta Smart PRO...

Страница 8: ...A 9 8 14 9 8 8 B A 8 14 8 8 0 1 0 C 1 0D A 4 27 1E2446 A 0 1 C 0 1 0D A 4 27 1E2446 A 9 8 A 8 A 8 8 F Teldat S A 1 About This Manual Regesta Smart PRO 3...

Страница 9: ...ces Teldat Dm781 I Cellular Interface Teldat Dm748 I Software Updating 1 10 Technical Support Contact information Web http www teldat com Tel 34 918 076 565 Fax 34 918 076 566 Email support teldat com...

Страница 10: ...e and extreme environments Thanks to their ruggedized mechanics and special characteristics which allow them to bear extreme temperatures these routers are particularly suited for industrial environme...

Страница 11: ...gabit Ethernet port 1 RS232 MultiRange power input 48 72 VDC 110 240 VAC RWRTHR6ZAC Regesta Smart PRO 1 LAN Gigabit Ethernet port 1 WAN Combo Gigabit Ethernet port 4xPort Gigabit Ethernet Switch 1 RS2...

Страница 12: ...rnet port 4xPort Gigabit Ethernet Switch 1 RS232 1xWWAN Bands LTE 1 3 5 7 8 20 38 40 41 WCDMA 1 5 8 MultiRange power input 48 72 VDC 110 240 VAC 2 3 Hardware Features The following lists the hardware...

Страница 13: ...he LEDs indicate the following Table 2 LEDs LED Associated Inter face Status Description ON Power Off Green Device is not powered Device is powered SW Ethernet Switch in terface Off Green Ethernet Swi...

Страница 14: ...d Flashing Data is being transferred SFP Ethernet WAN in terface SFP Off Green SFP is not used Ethernet SFP connection link is established S1 Multi standard seri al interface 1 Off Green Serial port 1...

Страница 15: ...out the CONF connector refer to Console Connector as Serial Port CONF connector on page 25 Configuration Connector on page 35 Configuration Interface on page 38 C WAN Gigabit Ethernet SFP connector Fo...

Страница 16: ...uration of each port depends on the hardware configuration of the device model For more information on the connector for serial ports RS 485 2 4 wires RS 422 and DCE RS 232 refer to RS232 option RS 23...

Страница 17: ...accessories to attach the device to a DIN rail mount For further in formation on this accessory please see section Wall mounting on page 17 B Platform where the label containing product information i...

Страница 18: ...Power Supply The Regesta Smart PRO DC version is powered with an external DC source Nominal power voltages are 12 72 V DC 2 5 3 Multi Range MR Power Supply The Regesta Smart PRO MR version can be pow...

Страница 19: ...he Regesta Smart PRO includes a protective case for connectors Its main function is to prevent accidental electric al discharges which can prove dangerous Thanks to the casing direct contact with conn...

Страница 20: ...Slide up the case as shown Teldat S A 3 Installing the Router Regesta Smart PRO 15...

Страница 21: ...3 Installing a DIN rail mount accessory The Regesta Smart PRO can be installed on a standard DIN rail To mount it on a DIN rail a special kit is needed This kit is included in the delivery The DIN rai...

Страница 22: ...ttached to a wall thanks to the 3 perforations To ensure it is properly fastened screws must be installed in said holes Before mounting the device on the wall remove the protective casing The followin...

Страница 23: ...Fig 13 Perforations for wall mounting 3 Installing the Router Teldat S A 18 Regesta Smart PRO...

Страница 24: ...llowing instructions carefully before connecting the router 4 1 1 Power Connector pins The power connector is located in the connector panel Fig 14 Power Supply Connector Depending on the model the Re...

Страница 25: ...by IEC 60227 is acceptable Warning All interconnected communication devices should be plugged to THE SAME GROUNDED POWER OUTLET which should at the same time be of good quality lower than 10 ohms Whe...

Страница 26: ...egesta Smart PRO incorporates one 10 100 1000 BaseT Gigabit Etherent port with automatic MDI MDIX to connect to a local area network LAN This interface is totally independent from the switch if presen...

Страница 27: ...ctive UL and or CSA registered component for North America 47 CFR Part 15 Class A Warning Laser Radiation Do not use optical instruments directly or without proper protection CLASS 1 LASER PRODUCT The...

Страница 28: ...ctor while the RF2 connector is linked to the AUX con nector Using these antennas in the Regesta Smart PRO router improves the quality of the signal received and transmitted by the WWAN module Some ce...

Страница 29: ...cies RF For optimum coverage follow these steps Whenever possible place the antenna where there are no physical obstacles Obstacles between the antenna and the base station degrade the wireless signa...

Страница 30: ...rt The latter has the following char acteristics 1 DCE port 2 RS 232 norm 3 Maximum speed of 115200 bps 4 Only the following signals are available RxD TxD and GND See Configur ation Connector on page...

Страница 31: ...evice s protective case and are labeled SIM1 and SIM2 In installations where only one SIM card is required we recommend installing it in the SIM1 tray Warning Never install the SIM cards when the devi...

Страница 32: ...socket 2 Fig 23 Location of the SIM1 and SIM2 trays 4 3 2 Procedure to install the SIM Once the appropriate SIM is selected carry out the following steps 1 Push the fastening in the direction indicat...

Страница 33: ...h its default configuration 1 Press the RST button The device restarts with the S C and L LEDs in the off state and the ON LED lights up in green 2 Keep pressing the RST button while the S LED flashes...

Страница 34: ...for the service For further information please see manual Teldat Dm781 I Cellular Interface 4 6 Updating the software The Regesta Smart PRO router can be updated to new releases Please contact your d...

Страница 35: ...he router s default configuration establishes the following IP address and access mask IP address 192 168 1 1 IP mask 255 255 255 0 Note Some devices leave the factory with customized settings This pe...

Страница 36: ...ereby Teldat S A declares that telecommunications equipment Regesta Smart PRO complies with Directive 2014 30 EU EMC Directive 2014 35 EU LVD Directives 2011 65 EU and 2015 863 EU RoHS of the European...

Страница 37: ...procedures and marking 5 6 National Restrictions In accordance with Article 10 of 2014 53 EU we inform you that national restrictions and requirements may apply when it comes to authorization These ca...

Страница 38: ...ste disposal facility at the end of its useful service life El s mbolo del contenedor con la cruz que se encuentra en el aparato significa que cuando el equipo haya llegado al final de su vida til deb...

Страница 39: ...A BI DA BI DB BI DB BI DA BI DA BI DB BI DC BI DC BI DB BI DD BI DD A 1 2 WAN Base T Connector RJ45 WAN RJ45 PIN FE Signals GE Signals 1 2 3 4 5 6 7 8 BI DA BI DA BI DB BI DB BI DA BI DA BI DB BI DC B...

Страница 40: ...I DA BI DB BI DB BI DA BI DA BI DB BI DC BI DC BI DB BI DD BI DD A 1 5 WWAN RF Connectors Devices equipped with this interface have two SMA female connectors installed SMA Female PIN ANT Internal Exte...

Страница 41: ...X _4H_TX 4H_RX 4H_RX A 1 9 Power Supply Connector 2 wires terminal block 5 08 mm pitch AC powered version Phase and Neutral connectors without assignation DC powered version V and V connectors with po...

Страница 42: ...h isolation for E2 up to 10 KV A 2 4 Switch Interface PROTOCOLS Ethernet 802 3 PORTS 4 port or 2 port switch managed with MDI MDX auto detection depending on the model SPEED 10 100 1000 Mbps Base T CO...

Страница 43: ...iguration Interface LOCAL TERMINAL V 24 115200 8 N 1 without flow control CONNECTOR RJ 45 female on the connector panel A 2 8 RS 232 Serial Interface STANDARDS RS 232 Asynchronous serial port with con...

Страница 44: ...8 mm pitch A 2 10 3 MR model NOMINAL 110 240 V AC 48 72 V DC ABSOLUTE MAXIMUM 85 264 V AC 40 85 V DC FREQUENCY 50 60 Hz AC MAXIMUM POWER 10 W CONNECTOR Terminal Block 2 Poles 5 08 mm pitch A 2 11 Dime...

Страница 45: ...ations Technology LTE Bands Frequencies Conducted Transmit Power Band 1 Tx 1920 1980 MHz Rx 2110 2170 MHz 23 dBm 2 dB Band 3 Tx 1710 1785 MHz Rx 1805 1880 MHz 23 dBm 2 dB Band 7 Tx 2500 2570 MHz Rx 26...