background image

 

Vers. 002

 

Energy 2510 B

 

GB

1   FOREWORD 

 

 Refer carefully to this man-

ual  before  performing  any  operation  on  the 
power generator set.
 
 
1.1   Purpose and scope of this manual 
 
This manual has been drawn up by the Manufac-
turer in order to provide basic information and in-
structions for performing every operation for ser-
vicing  and  using  the  generating  set  in  a  proper 
and safe manner. 
It  is  an  integral  part  of the  generating  set  equip-
ment, must be kept with care throughout the life 
of the same, and must be protected against any 
agent which could damage it. 
It must follow the generating set if this is installed 
on  a  new  vehicle,  or  if  its  ownership  changes 
hands. 
The  information  in  this  manual  is  addressed  to 
the personnel in charge of installing the generat-
ing  set,  and  to  all  those  involved  in  its  mainte-
nance and use. 
This  manual  sets  out  the  purpose  the  machine 
was  designed  for,  and  contains  all  the  informa-
tion required to guarantee that it is used in a safe 
and proper manner. 
Constant  compliance  with  the  instructions  laid 
down  here  will  guarantee  the  safety  of the  user, 
operating  economy  and  longer  life  of  the  ma-
chine. 
To  facilitate  reference,  this  manual  has  been 
subdivided into chapters specifying the main no-
tions contained therein; for quick consultation, re-
fer to the table of contents. 
The  most  important  parts  of  the  text  are  in  bold 
letters and preceded by symbols described here 
below. 
It  is  strongly  recommended  that  you  read  the 
contents of this manual and the reference docu-
ments  carefully;  doing  so  is  essential  to the  cor-
rect  long-term  performance  and  reliability  of  the 
generator set and the prevention of injury and/or 
damage. 
 
Note:  The  information  contained  in  this  publica-
tion  was  correct  at  the  time  it  went  to  print,  but 
may be modified without advance notice. 
 
 
 
 
 

 
1.2   Symbols and Definitions 
 
"Graphic safety symbols” have been employed in 
this  booklet  to  identify  different  levels  of  danger 
or important information. 
 

  This  means  that  you  must 

pay  attention  to  avoid  serious  consequences 
which might lead to serious accidents or damage 
the health of the operators. 
 

  This  means  a  potentially 

hazardous  situation  which  could  lead  to  acci-
dents or damage to property. 
 

 This calls the user’s attention 

to  a  potentially  dangerous  situation  which  could 
cause malfunction or damage the machine. 
 
The drawings are only provided by way of exam-
ple. 
Even though the machine you actually have may 
differ from the illustrations contained in this man-
ual,  safety  and  information  about  the  same  are 
guaranteed. 
The  manufacturer,  as  part  of  his  policy  of  con-
stant product development and updating, may in-
troduce changes without giving any notice. 
 
 
1.3   General Information 
 
The ENERGY generating set has been designed 
for installation on vehicles. It can deliver power at 
a voltage of 230 VAC 50 Hz. 
The  ENERGY  2510  B  model  must  be  fed  lead-
free petrol. 
In  order  to  achieve  a  low  noise  level,  the  EN-
ERGY  
series  generating  sets  are  provided  with 
internally insulated sound-proofing cases. 
They can be accessed easily in order to perform 
maintenance  work,  and  are  provided  with  a  re-
mote  control  panel  which  can  be  installed  inside 
the vehicle. 
The  generating  sets  can  be  connected  to  the 
tank  of  the  vehicle  as  long  as  the  fuel  type  is 
compatible.  Otherwise,  install  a  special  tank 
which can be supplied as an option. 
 
 
 

Содержание ENERGY 2510B

Страница 1: ...Energy 2510 B Vers 022 1 GB INDEX USER S OPERATING INSTRUCTION AND INSTALLATION MANUAL GB ENERGY 2510B v 002 April 2015 GENERATORS...

Страница 2: ...ection 12 4 8 Auxiliary optional fuel pump connection 12 4 9 Optional tank installation instructions 13 4 10 Fuel reserve 14 4 11 Battery charger 14 4 11 1 Auxiliary Battery Charger 14 4 12 Connecting...

Страница 3: ...When the generator remains idle for at least three weeks old unleaded petrol sediments could build up inside the carburettor These sediments can seriously damage the engine and it is therefore COMPULS...

Страница 4: ...written ap proval Machine GENERATING SET Model ENERGY 2510 B Maximum power 2 5 KW 3000 r p m Serial number Directive of reference Machine Directive 2006 42 CE Low Voltage Directive 2006 95 CE Electro...

Страница 5: ...g term performance and reliability of the generator set and the prevention of injury and or damage Note The information contained in this publica tion was correct at the time it went to print but may...

Страница 6: ...t 8 Electronic control panel 9 Gas pipe and cable outlet block 10 Sliding surface locking screw 11 Fuel pipe 12 Sliding surface all out locking screw 2 2 Identification plate Fig 2 1 Generating set mo...

Страница 7: ...2 Voltage Frequency V Hz 230 50 Continuous current output A Vdc 10 12 Rotor insulation class H Stator insulation class F Cooling Centrifugal fan GENERATOR 2510 B Overall weight kg 56 Dimensions L X W...

Страница 8: ...y or damage to people or prop erty Installation must be per formed by qualified and adequately trained personnel only 4 2 Instructions for fastening the generating set The ENERGY 2510 B generating set...

Страница 9: ...ose of preventing hot air from spreading inside the generator compartment The brackets of the generator must be moved in order to fasten the Energy 2510B on the bearing surface On both sides remove th...

Страница 10: ...in Table 1 To this end the generating set is provided with two special terminals Fig 13 Ref 2 used to con nect the positive and negative poles of the bat tery Connect the cable of the positive pole re...

Страница 11: ...es must be con nected Use the special cable outlet Fig 11 Ref 1 to prevent water seeping into the generating set Although the generating set is equipped with a special internal thermal cut out to cut...

Страница 12: ...ning also see paragraph 4 10 Cable from the generating set to the auxiliary battery charger optional From the bipolar connector Fig 13 Ref 6 it is possible to de rive supply for an RCB battery charge...

Страница 13: ...fference requirements an electric fuel pump can be installed available as an optional part code 00507 which can easily overcome over 1 metre level differences between the fuel tank and the generating...

Страница 14: ...the fuel level inside the tank has gone below the safe reserve level 4 11 Battery charger ENERGY 2510 B generating sets are equipped with a battery charger which can deliver current of approximately...

Страница 15: ...perating noise an optional additional silencer can be in stalled externally The additional silencer kit code 02482 consists of A silencer code 02019 Fig 21 Ref 1 A one metre long section of flexible s...

Страница 16: ...the muffler terminal Fig 25 Ref 2 Now insert the hose code 00443 Fig 25 Ref 5 on the coupling Fig 25 Ref 3 Lock the hose with the clamp code 00543 Fig 25 Ref 4 Fix the flexible hose Fig 26 Ref 2 to th...

Страница 17: ...to insulate the generat ing set when the vehicle is connected to an ex ternal electric input network Connect the relay Fig 29 according to the fol lowing instructions Connect the two wires of the 230...

Страница 18: ...s or the cut out switches with others having higher amper age Should any electrical part need checking this must only be done with the engine turned off and by specialised personnel The generating set...

Страница 19: ...has started and reached steady state Before stopping the generating set disconnect or at least turn off the connected users To make the best use of the generating sets re member that even minor overl...

Страница 20: ...nctionality of panel is necessary to completely re initialize contact the Service 6 7 Automatic Version optional If you wish the start up batteries to be recharged automatically in the En 2510 B gener...

Страница 21: ...anual in order to avoid accidentally starting up the generating set 7 1 Service check list See table at the bottom of page 24 7 2 Maintenance not requiring specialised personnel To perform this kind o...

Страница 22: ...will be more fluid and emptying will be quicker and more thorough Undo the special cap on the soil sump Fig 34 Ref 1 which can be reached through a special hole under the sound proofing case Fig 35 Re...

Страница 23: ...W20EP U W20EPR U ND or else spark plugs made by other manufacturers but compatible with the above Never use spark plugs with a different tempera ture degree from those listed above Take the cap off t...

Страница 24: ...NE MAINTENANCE SCHEDULE To be performed after the period of time or the number of running hours listed here whichever the earlier Every use First Month or 20 hours Every 3 Months or 50 hours Every 6 M...

Страница 25: ...el tap and running the generator set until it stops It is also essential that you never use old unleaded petrol as it can un dergo chemical modifications and seriously damage the engine Failure to obs...

Страница 26: ...y period shall end no later than 14 months 16 months if delivered outside of Europe after ex factory delivery In any case the costs of lubricants and consumables shall be charged Any transport expense...

Страница 27: ...EN GREY PURPLE WHITE BLACK PINK GREY GREEN PINK YELLOW RED WHITE PURPLE BLACK BLUE BROWN BLACK RED ORANGE ORANGE BROWN BROWN GREEN PINK BLACK GREY YELLOW BLUE RED BLUE WHITE ORANGE ORANGE ORANGE ORANG...

Страница 28: ...l float Startup battery connection terminals Diode bridge protection fuse Battery charger terminal Pos 13 14 15 16 17 18 19 20 21 22 A Description Electronic control panel Electronic control panel con...

Страница 29: ...Vers 002 Energy 2510 B 29 GB DRAWING FOR SPARE PARTS LIST ENERGY 2510 B...

Страница 30: ...Energy 2510 B Vers 002 30 GB...

Страница 31: ...Vers 002 Energy 2510 B 31 GB...

Страница 32: ...en f r Haube Aislante Trasero Cap 8 03905 N 1 Isolante Destro Cofano Isolation Droite Capot Isolatie rechts voor kap Right hood insulation Isolierung rechts f r Haube Aislante Derecho Cap 9 03904 N 1...

Страница 33: ...re 22 01177 N 1 Terminale di scarico Partie terminale pot d chapp Uiteinde uitlaat Muffler end pipe Auspuff Endrohr Tubo de descarga 23 01830 N 1 Convogliatore marmitta Convoyeur pot d chappement Gele...

Страница 34: ...io Generatore trier Fixation du G n rateur De Inplanting van de stijgbeu gel van de Generator Bracket Implantation of the Generator Steigb gel Einpflanzung des Generators Implantaci n del estribo del...

Страница 35: ...t rmica 49 01407 N 1 Interruttore Manuale Autom Interrupteur Ma nuel Automatique Schakelaar handb autom Manual Automatic Switch Schalter Hand Auto Interruptor Manual Autom 50 01607 N 1 Fusibile 15A Fu...

Страница 36: ...63 02050 N 1 Rondella alternatore Rondelle de l alternateur Onderlegring dynamo Alternator washer Scheibe der Lichtmaschine Arandela alternador 64 02051 N 1 Cuscinetto alternatore Palier de l alterna...

Страница 37: ...ltre air Luchtfilter Air cleaner Luftfilter Filtro aire 78 02271 N 1 Coperchio filtro aria Couvercle du filtre air Kap luchfilter Air cleaner lid Luftfilterdeckel Tapa filtro aire 79 00974 N 1 Motore...

Страница 38: ...Verlengstuk Extension Verl ngerung Extensi n 89 00810 N 1 Tappo Bouchon Dop Cap Kappe Tap n 90 01128 N 1 Termostato 90 Thermostat 90 Thermostaat 90 Thermostat 90 Thermostat 90 Termostato 90 91 01834 N...

Страница 39: ...Vers 002 Energy 2510 B 39 GB Notes...

Страница 40: ...Energy 2510 B Vers 002 40 GB...