background image

 

 

Energy 2510 B 

Vers. 022

 

12 

GB

4.6  Auxiliary electric cable connection 
 
All  3  auxiliary  cables  to  connect  are  equipped 
with a polarized connector. 
One  cable  is  necessary  for  generator  operation, 
while the other 2 are optional cables. 

  Cable  from  the  generating  set  to  the  control 

panel  (mandatory).  It  is  included  in  the  stan-
dard supply and is 5 metres long. Check that 
its length is sufficient to cover the chosen rout 
between  the  generating  set  and  the  control 
panel.  Optional  cables  in  longer  sizes  are 
also available. 

After leading the cable through the cable  out-
let  block  (Fig.11  Ref.1)  connect  the  white 
connector to  the fixed  connector (Fig.13  Ref. 
9)  provided  inside  the  generating  set,  check-
ing that the plugging direction is correct. 

  Cable from the generating set to the auxiliary 

fuel  pump  and  fuel  tank  reserve  (optional). 
From the three-pole connector (Fig.13 Ref.8) 
it  is  possible  to  take  two  cables  to  supply 
electric  input  to  an  auxiliary  fuel  pump;  also 
see paragraph 4.8. 
From the  same connector  (Fig.13  Ref.8)  it  is 
also  possible  to  take  the  signal  for  tank  fuel 
warning; also see paragraph 4.10. 

  Cable from the generating set to the auxiliary 

battery  charger  (optional).  From  the  bipolar 
connector  (Fig.13  Ref.6)  it  is  possible  to  de-
rive supply for an RCB battery charge regula-
tor  via  two  4  mm

2

  cables;  also  see  para-

graph 4.11.1. 

 
 
4.7  Electronic control panel connection 
 

 

 
Choose  your  required  position  for  the  control 
panel  inside  the  vehicle  and  drill  a  30  x  32  mm 
rectangular  hole.  After  letting  out  of  the  hole  the 
connecting cable coming from the generating set 
(paragraph 4.6) connect the cable black connec-

tor on the back of the electronic control panel. Fix 
the electronic control panel (Fig.14) by using 3 x 
20 mm self-tapping screws, making sure that the 
rear  part  does  not  interfere  with  other  surfaces. 
Apply  light pressure to fix the plastic frame, until 
the anchoring tabs click in. 
 
 
4.8  Auxiliary (optional) fuel pump connection 
 
If  the  distance  that  fuel  must  cover  between  the 
fuel tank and the generating set is too long or the 
tank is installed at a lower level than the generat-
ing set, the fuel pump installed inside the gener-
ating  set  may  find  it  difficult  to  take  fuel  in  from 
the tank by suction. In this case, an auxiliary op-
tional fuel pump (code 00507) should be installed 
as close as possible to the tank for easy priming. 
 

 

 

Содержание ENERGY 2510B

Страница 1: ...Energy 2510 B Vers 022 1 GB INDEX USER S OPERATING INSTRUCTION AND INSTALLATION MANUAL GB ENERGY 2510B v 002 April 2015 GENERATORS...

Страница 2: ...ection 12 4 8 Auxiliary optional fuel pump connection 12 4 9 Optional tank installation instructions 13 4 10 Fuel reserve 14 4 11 Battery charger 14 4 11 1 Auxiliary Battery Charger 14 4 12 Connecting...

Страница 3: ...When the generator remains idle for at least three weeks old unleaded petrol sediments could build up inside the carburettor These sediments can seriously damage the engine and it is therefore COMPULS...

Страница 4: ...written ap proval Machine GENERATING SET Model ENERGY 2510 B Maximum power 2 5 KW 3000 r p m Serial number Directive of reference Machine Directive 2006 42 CE Low Voltage Directive 2006 95 CE Electro...

Страница 5: ...g term performance and reliability of the generator set and the prevention of injury and or damage Note The information contained in this publica tion was correct at the time it went to print but may...

Страница 6: ...t 8 Electronic control panel 9 Gas pipe and cable outlet block 10 Sliding surface locking screw 11 Fuel pipe 12 Sliding surface all out locking screw 2 2 Identification plate Fig 2 1 Generating set mo...

Страница 7: ...2 Voltage Frequency V Hz 230 50 Continuous current output A Vdc 10 12 Rotor insulation class H Stator insulation class F Cooling Centrifugal fan GENERATOR 2510 B Overall weight kg 56 Dimensions L X W...

Страница 8: ...y or damage to people or prop erty Installation must be per formed by qualified and adequately trained personnel only 4 2 Instructions for fastening the generating set The ENERGY 2510 B generating set...

Страница 9: ...ose of preventing hot air from spreading inside the generator compartment The brackets of the generator must be moved in order to fasten the Energy 2510B on the bearing surface On both sides remove th...

Страница 10: ...in Table 1 To this end the generating set is provided with two special terminals Fig 13 Ref 2 used to con nect the positive and negative poles of the bat tery Connect the cable of the positive pole re...

Страница 11: ...es must be con nected Use the special cable outlet Fig 11 Ref 1 to prevent water seeping into the generating set Although the generating set is equipped with a special internal thermal cut out to cut...

Страница 12: ...ning also see paragraph 4 10 Cable from the generating set to the auxiliary battery charger optional From the bipolar connector Fig 13 Ref 6 it is possible to de rive supply for an RCB battery charge...

Страница 13: ...fference requirements an electric fuel pump can be installed available as an optional part code 00507 which can easily overcome over 1 metre level differences between the fuel tank and the generating...

Страница 14: ...the fuel level inside the tank has gone below the safe reserve level 4 11 Battery charger ENERGY 2510 B generating sets are equipped with a battery charger which can deliver current of approximately...

Страница 15: ...perating noise an optional additional silencer can be in stalled externally The additional silencer kit code 02482 consists of A silencer code 02019 Fig 21 Ref 1 A one metre long section of flexible s...

Страница 16: ...the muffler terminal Fig 25 Ref 2 Now insert the hose code 00443 Fig 25 Ref 5 on the coupling Fig 25 Ref 3 Lock the hose with the clamp code 00543 Fig 25 Ref 4 Fix the flexible hose Fig 26 Ref 2 to th...

Страница 17: ...to insulate the generat ing set when the vehicle is connected to an ex ternal electric input network Connect the relay Fig 29 according to the fol lowing instructions Connect the two wires of the 230...

Страница 18: ...s or the cut out switches with others having higher amper age Should any electrical part need checking this must only be done with the engine turned off and by specialised personnel The generating set...

Страница 19: ...has started and reached steady state Before stopping the generating set disconnect or at least turn off the connected users To make the best use of the generating sets re member that even minor overl...

Страница 20: ...nctionality of panel is necessary to completely re initialize contact the Service 6 7 Automatic Version optional If you wish the start up batteries to be recharged automatically in the En 2510 B gener...

Страница 21: ...anual in order to avoid accidentally starting up the generating set 7 1 Service check list See table at the bottom of page 24 7 2 Maintenance not requiring specialised personnel To perform this kind o...

Страница 22: ...will be more fluid and emptying will be quicker and more thorough Undo the special cap on the soil sump Fig 34 Ref 1 which can be reached through a special hole under the sound proofing case Fig 35 Re...

Страница 23: ...W20EP U W20EPR U ND or else spark plugs made by other manufacturers but compatible with the above Never use spark plugs with a different tempera ture degree from those listed above Take the cap off t...

Страница 24: ...NE MAINTENANCE SCHEDULE To be performed after the period of time or the number of running hours listed here whichever the earlier Every use First Month or 20 hours Every 3 Months or 50 hours Every 6 M...

Страница 25: ...el tap and running the generator set until it stops It is also essential that you never use old unleaded petrol as it can un dergo chemical modifications and seriously damage the engine Failure to obs...

Страница 26: ...y period shall end no later than 14 months 16 months if delivered outside of Europe after ex factory delivery In any case the costs of lubricants and consumables shall be charged Any transport expense...

Страница 27: ...EN GREY PURPLE WHITE BLACK PINK GREY GREEN PINK YELLOW RED WHITE PURPLE BLACK BLUE BROWN BLACK RED ORANGE ORANGE BROWN BROWN GREEN PINK BLACK GREY YELLOW BLUE RED BLUE WHITE ORANGE ORANGE ORANGE ORANG...

Страница 28: ...l float Startup battery connection terminals Diode bridge protection fuse Battery charger terminal Pos 13 14 15 16 17 18 19 20 21 22 A Description Electronic control panel Electronic control panel con...

Страница 29: ...Vers 002 Energy 2510 B 29 GB DRAWING FOR SPARE PARTS LIST ENERGY 2510 B...

Страница 30: ...Energy 2510 B Vers 002 30 GB...

Страница 31: ...Vers 002 Energy 2510 B 31 GB...

Страница 32: ...en f r Haube Aislante Trasero Cap 8 03905 N 1 Isolante Destro Cofano Isolation Droite Capot Isolatie rechts voor kap Right hood insulation Isolierung rechts f r Haube Aislante Derecho Cap 9 03904 N 1...

Страница 33: ...re 22 01177 N 1 Terminale di scarico Partie terminale pot d chapp Uiteinde uitlaat Muffler end pipe Auspuff Endrohr Tubo de descarga 23 01830 N 1 Convogliatore marmitta Convoyeur pot d chappement Gele...

Страница 34: ...io Generatore trier Fixation du G n rateur De Inplanting van de stijgbeu gel van de Generator Bracket Implantation of the Generator Steigb gel Einpflanzung des Generators Implantaci n del estribo del...

Страница 35: ...t rmica 49 01407 N 1 Interruttore Manuale Autom Interrupteur Ma nuel Automatique Schakelaar handb autom Manual Automatic Switch Schalter Hand Auto Interruptor Manual Autom 50 01607 N 1 Fusibile 15A Fu...

Страница 36: ...63 02050 N 1 Rondella alternatore Rondelle de l alternateur Onderlegring dynamo Alternator washer Scheibe der Lichtmaschine Arandela alternador 64 02051 N 1 Cuscinetto alternatore Palier de l alterna...

Страница 37: ...ltre air Luchtfilter Air cleaner Luftfilter Filtro aire 78 02271 N 1 Coperchio filtro aria Couvercle du filtre air Kap luchfilter Air cleaner lid Luftfilterdeckel Tapa filtro aire 79 00974 N 1 Motore...

Страница 38: ...Verlengstuk Extension Verl ngerung Extensi n 89 00810 N 1 Tappo Bouchon Dop Cap Kappe Tap n 90 01128 N 1 Termostato 90 Thermostat 90 Thermostaat 90 Thermostat 90 Thermostat 90 Termostato 90 91 01834 N...

Страница 39: ...Vers 002 Energy 2510 B 39 GB Notes...

Страница 40: ...Energy 2510 B Vers 002 40 GB...

Отзывы: