www.tekvox.com
MV71-4K
79064 User Manual
3.3 Command List
The MV71 is controlled or operated through the commands from RS232 or IP. The command
contains the following:
•
Source Control
•
Advanced Control
•
EDID Management
Command header
: ATM
Length
:
≤
255
Command
: xxxxxxx
Read/Write
: W/R
Parameter data
: xx (N byte) Carriage Return Termination is not required. All values are in ASCII.
3.3.1 Source Control
3.3.1.1 Viewing Mode
Function Item
Command
Description
Screen
Layout
Single Window
ATM 09 SCR_LYT W 1
Switch to the single window.
Dual Windows
ATM 09 SCR_LYT W 2
Switch to the double windows.
Triple Windows
ATM 09 SCR_LYT W 3
Switch to the triple windows.
Quadruple Windows
ATM 09 SCR_LYT W 4
Switch to the quadruple windows.
3.3.1.2 Video Input Selection
Function
Item
Command
Description
Video
Input
Selection
Viewer 1
ATM 0A VDO_IPT W 1
p
p = Input Number (1 ~ 7)
Send Input
p
as view window video
output
Viewer 2
ATM 0A VDO_IPT W 2
p
Viewer 3
ATM 0A VDO_IPT W 3
p
Viewer 4
ATM 0A VDO_IPT W 4
p
3.3.1.3 Audio Input Selection
Function
Item
Command
Description
Audio
Input
Selection
Select audio input
ATM 09 ADO_IPT W
p
p = Input Number (1 ~ 7)
Set Input
p
as audio output
Audio
Input
Config.
Set input to use
HDMI or external
audio
ATM 0A AUD_MOD W
p
q
p = Input Number (1 ~ 6)
q = Audio Mode (0 = HDMI Audio;
1 = External Audio)
Query
Audio
Input
Config.
Check whether
input is using HDMI
or external audio
ATM 09 AUD_MOD R
p
p = Input Number (1 ~ 6)
0 = HDMI Audio; 1 = External Audio