![Tektronix WVR6020 Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/tektronix/wvr6020/wvr6020_technical-reference_1077619086.webp)
Incoming Inspection
A/V Delay Test (Option
AVD)
1.
Connect an SDI video signal from a SIGNAL output of the DVG7 to the SDI
A input of the WVR instument. Terminate the loop-through.
2.
Set the signal generator for AV Timing Mode as follows:
a.
Press the
MODULE
button until
TG700:PRESET
appears and then
press
ENTER
.
b.
Press
<
to display
Factory Default
, and then press
ENTER
.
c.
Press
MODULE
until the module type you are using appears.
d.
Press
Ù
until
VIDEO
appears and then press
ENTER
.
e.
Press
Ù
until
AV Timing Mode
appears.
f.
Press
>
to select
ON
and then press
ENTER
.
g.
Press
CANCEL
to return to the previous menu.
h.
Press
Ù
until
AUDIO (EMBEDDED)
appears.
i.
Press
<
until
GROUP 1
appears and then press
ENTER
.
j.
Press
>
until
STATUS: ENABLED
appears and then press
ENTER
.
3.
On the WVR instrument, press the
FACTORY
button to restore factory
settings.
4.
Press and hold the
MEAS
button.
5.
Select
Display Type > AV Delay
.
6.
Press the
<
navigation key to return to the previous menu level.
7.
Set
AV Delay Enable
to
On
.
8.
Press the
MEAS
button to close the menu.
9.
Check that the AV Delay readout is green and that it indicates less than 0.005 s.
The number in the Fields readout will depend on the video standard in use.
10.
Enter Pass or fail in the test record.
72