![Tektronix TLA6400 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/tektronix/tla6400-series/tla6400-series_technical-reference_1078215016.webp)
Speci
fi
cations
Table 8: Probing speci
fi
cations
Characteristic
Description
Number of channels
TLA6401
34
TLA6402
68
TLA6403
102
TLA6404
136
Probe connector location
Lower right side of the instrument
Probes user removable
Remove probes by pressing button on the probe connector.
Analog outputs
Number of outputs
Any four of the channels can be mapped to the four analog outputs with the appropriate
PowerFlex option.
All four outputs can be used at the same time.
A given input channel cannot be routed to more than one output at the same time.
Attenuation
(Typical)
10 x, 5 x
P5910 General Purpose
probe
P5934 Mictor probe
P5960 DMAX probe
Bandwidth
(Typical)
2 Ghz (-3dB)
1.5 Ghz (-3dB)
2 Ghz (-3dB)
Accuracy (gain and offset)
(Typical)
±(80 mV + 2% of signal amplitude)
Channel-to-channel skew
(Typical)
±500 ps
Delay time from probe tip to
analog signal out
(Typical)
11.9 ns
Standard:
4
fi
xed channels
PowerFlex
Options:
Any input channel to 4 channels
Input voltage range, dynamic
(Typical)
-2.5 V to +5 V
Input voltage range, absolute
maximum
(Typical)
-4.5 V to +13 V
Threshold range and step size
Can be set from -2.0 V to +4.5 V in 5 mV increments
Threshold accuracy
(Certi
fi
able parameter)
±(50 mV + 1% of the threshold voltage setting)
Number of thresholds
Each channel has an independent threshold control.
6
TLA6400 Series Product Speci
fi
cations & Performance Veri
fi
cation