Speci
fi
cations
Table 7: TLA5000 clocking (cont.)
Characteristic
Description
Setup and hold window range
For each channel, the setup and hold window can be moved from +8.0 ns
(Ts) to -8.0 ns (Ts) in 0.125 ns steps. The hold time follows the setup time
by the setup and hold window size.
Maximum synchronous clock rate
235 MHz in full speed mode (4.25 ns minimum between active clock
edges)
2X Demux clocking
Any individual channel may be demultiplexed with its partner channel.
Channels demultiplex as follows:
TLA5203, TLA5204
A3(7:0) to/from
A2(7:0) to/from
A1(7:0) to/from
A0(7:0) to/from
C3(7:0) to/from
C2(7:0) to/from
E3(7:0) to/from
E2(7:0) to/from
CK3 to/from
CK2 to/from
CK1 to/from
CK0 to/from
D3(7:0)
D2(7:0)
D1(7:0)
D0(7:0)
C1(7:0)
C0(7:0)
E1(7:0) (TLA5204 only)
E0(7:0) (TLA5204 only)
Q2 (TLA5204 only)
Q3 (TLA5204 only)
Q0
Q1
Any individual channel may be demultiplexed with its partner channel.
Channels demultiplex as follows:
TLA5201, TLA5202
A3(7:0) to/from
A2(7:0) to/from
A1(7:0) to/from
A0(7:0) to/from
C3(7:0)
C2(7:0)
D1(7:0) (TLA5202 only)
D0(7:0)( TLA5202 only)
Time between Demultiplex clock edges
(Typical)
Same limitations as normal synchronous acquisition
4X Demux clocking
Unlike 2X demultiplexing, the channels within a group of four cannot
arbitrarily drive the others.
TLA5203, TLA5204
E3(7:0) to
A3(7:0) to
A1(7:0) to
C3(7:0) to
CK3 to
CK1 to
E2(7:0), E1(7:0), E0(7:0) (TLA5204 only)
A2(7:0), D3(7:0), D2(7:0)
A0(7:0), D1(7:0), D0(7:0)
C2(7:0), C1(7:0), C0(7:0)
CK2, Q3, Q2 (TLA5204 only)
CK0, Q1, Q0
10
TLA5000 Series Product Speci
fi
cations & Performance Veri
fi
cation