WARNING.

Observe all safety precautions listed in this manual before using this product and any associated instruments.

Although some instruments and accessories would be used with non-hazardous voltages, there are situations where
hazardous conditions may be present. This product is intended for use by quali

fi

ed personnel who recognize shock hazards

and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and
maintenance information carefully before using the product. Refer to this manual for complete product speci

fi

cations. Before

performing any maintenance, disconnect the line cord and all test cables. Operators of this instrument must be protected
from electric shock at all times. The responsible body must ensure that operators are prevented access and/or insulated from
every connection point. In some cases, connections must be exposed to potential human contact. Product operators in these
circumstances must be trained to protect themselves from the risk of electric shock. If the circuit is capable of operating at or
above 1000 volts, no conductive part of the circuit may be exposed.

WARNING.

Use properly rated load wires. All load wires must be heavy enough not to overheat when carrying the maximum

short-circuit output current of the power supply. If there is more than one load, then any pair of load wires must be capable
of safely carrying the full-rated short-circuit output current of the power supply.

WARNING.

Do not loosen any screw on this product. There are no user serviceable components inside.

WARNING.

To reduce risk of

fi

re and shock, ensure the mains supply voltage

fl

uctuations do not exceed 10% of the

operating voltage range.

Installing the System

This section contains information on how to install your PWS2000 power supply.

Unpack

 

the

 

instrument

 

and

 

check

 

that

 

you

 

received

 

all

 

the

 

items

 

listed

 

as

 

standard

 

accessories.

 

Check

 

that

 

you

 

also

 

received

 

any

 

other

 

accessories

 

that

 

you

 

ordered

 

with

 

your

 

instrument.

 

Check

 

the

 

Tektronix

 

Web

 

site

 

for

 

the

 

most

 

current

 

information.

To verify that the power supply is ready to use, follow these procedures:

Powering the Instrument On and Off

To power on the instrument follow these steps:

1.

Make all the connections.

2.

Properly set the 110 V / 220 V selector switch on the bottom of the instrument.

PWS2185, PWS2323, PWS2326, and PWS2721 User Manual

3

Содержание PWS2185

Страница 1: ...PWS2185 PWS2323 PWS2326 and PWS2721 Linear DC Power Supplies ZZZ User Manual P071275100 071 2751 00 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Страница 2: ......

Страница 3: ...PWS2185 PWS2323 PWS2326 and PWS2721 Linear DC Power Supplies ZZZ User Manual xx...

Страница 4: ...d by national copyright laws and international treaty provisions Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all pre...

Страница 5: ...tomer shall be responsible for paying all shipping charges duties taxes and any other charges for products returned to any other locations This warranty shall not apply to any defect failure or damage...

Страница 6: ......

Страница 7: ...siderations ix Preface x Key Features x Getting Started 1 Standard Accessories 1 Options and Optional Accessories 1 Specifications 2 Operating Requirements 2 Installing the System 3 Cleaning 6 Operati...

Страница 8: ...Table of Contents ii PWS2185 PWS2323 PWS2326 and PWS2721 User Manual...

Страница 9: ...gs To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings information before making connections to the product Power disconnect Th...

Страница 10: ...uld result in damage to this product or other property Symbols and Terms on the Product These terms may appear on the product DANGER indicates an injury hazard immediately accessible as you read the m...

Страница 11: ...and interruptions immunity 4 EN 61000 3 2 2006 AC power line harmonic emissions EN 61000 3 3 1995 Voltage changes fluctuations and flicker European contact Tektronix UK Ltd Western Peninsula Western...

Страница 12: ...unications Act per the following standard in accordance with ACMA CISPR 11 2003 Radiated and Conducted Emissions Group 1 Class A in accordance with EN 61326 1 2006 Australia New Zealand contact Baker...

Страница 13: ...n the environment around and within a product Typically the internal environment inside a product is considered to be the same as the external Products should be used only in the environment for which...

Страница 14: ...nt Category IV For measurements performed at the source of low voltage installation Measurement Category III For measurements performed in the building installation Measurement Category II For measure...

Страница 15: ...the environment and to reduce the use of natural resources we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropri...

Страница 16: ...cy 0 2 Basic current accuracy Less than 3 mVpp ripple and noise 20 user defined setup memories Model Description PWS2185 DC power supply 18 V 5 A 1 channel PWS2323 DC power supply 32 V 3 A 1 channel P...

Страница 17: ...tains detailed information about the instrument including specifications and how to verify performance 077 0482 XX One of the following North America Option A0 The factory sets the 110V 220V selector...

Страница 18: ...ing Altitude Operating 100 capability up to 2 000 meters Pollution Degree 2 For indoor use only Nominal Voltage Ratings There are two ranges for all models selectable by the line voltage selector swit...

Страница 19: ...operating at or above 1000 volts no conductive part of the circuit may be exposed WARNING Use properly rated load wires All load wires must be heavy enough not to overheat when carrying the maximum sh...

Страница 20: ...er supply First check that the AC power cord is firmly plugged into the power connector on the rear panel of the power supply You should also make sure that the AC power source you plugged the power s...

Страница 21: ...ndicated on the front panel of the unit 9 Check if the displayed voltage value is approximately the same value as the voltage setting Current output check To verify the basic current functions with a...

Страница 22: ...an the exterior surface perform the following steps 1 Remove loose dust on the outside of the power supply with a lint free cloth Use care to avoid scratching the display 2 Use a soft cloth dampened w...

Страница 23: ...d Recall function buttons 5 Number keys 0 to 9 and Esc for direct numeric entry 6 V Set I Set Menu and Output On Off function buttons 7 Power button Function button descriptions Button Description Set...

Страница 24: ...d then press the Enter button Max Volt Sets the maximum output voltage value to which you can set the instrument Key Lock When activated this feature locks the front panel controls and prompts for a p...

Страница 25: ...r The Volt meter display is active Lock Front panel controls are locked Enter password to unlock Rear Panel at a Glance 1 Cooling vents 2 110 V 220 V power connector 3 Factory test port CAUTION Unauth...

Страница 26: ...rom Set mode to Meter mode if you do not press any key for 3 seconds You can enable or disable the output of the power supply from the front panel by pushing the Output On Off button When the output i...

Страница 27: ...nstant voltage mode If the CC message appears the instrument is operating in constant current mode Crossover from the constant current mode to the constant voltage mode also occurs automatically in re...

Страница 28: ...Saving setups 1 After you set up the power supply voltage limit current limit and the maximum output voltage push the Save button 2 Use the number keys or the arrow keys to select the setup memory 1 t...

Страница 29: ...on To enable or disable this control 1 Push the Menu 2 Use the down arrow key to select OUT RECALL 3 Push Enter 4 Use the up arrow key to select On or Off 5 Push Enter 6 Push Esc to exit the menu syst...

Страница 30: ...any button or press any key To enable or disable this feature 1 Push Menu 2 Use the down arrow key to select Key Beep 3 Push Enter 4 Use the arrow keys to select On or Off 5 Push Enter 6 Push Esc to...

Страница 31: ...and Recall 7 Key Beep 14 M Max Volt Set 12 Menu button 8 Messages 8 N No power 4 O On off button 8 Operating requirements 2 Operation current limit adjustment 12 recalling setups 12 saving setups 12 v...

Отзывы: