![Tektronix PA3000 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/tektronix/pa3000/pa3000_installation-and-safety-manual_1078113027.webp)
TEK.COM | 25
DEMONSTRATION GUIDE
PA3000 Four-channel, Multi-phase AC/DC Power Analyzer
Standby Power Measurements (IEC 62301 Ed 2.0)
Bandwidth. For low power standby signals that have undesired high frequency components, low
bandwidth filters can be enabled. A low bandwidth 10 kHz filter is available through the Inputs
setup. Applying low pass filters might vary the RMS values of voltage, currents, and power as high
frequency components affect the RMS values.
Autozero. Use the Autozero
Run Now function under the System Configuration menu
to run autozero before running a standby power test. This will make sure that all the offsets
are compensated and the low current and power readings are accurate.
All settings can be saved for later use in the User Configuration menu.
METHOD 2: IEC 62301 ED. 2.0 FULL COMPLIANCE STANDBY POWER TESTING
(PWRVIEW SOFTWARE)
The PWRVIEW software along with PA3000 can test the standby power using full compliance
techniques of IEC 62301 Ed. 2.0 / EN50564. Measurements are made easy by using the PWRVIEW
software and for making accurate measurements for full compliance standby testing. The software
calculates real time instability and executes power averaging as required by the standard.
WHAT YOU WILL NEED — METHOD 2
•
PA3000 Power Analyzer
•
PC with PWRVIEW software installed
•
AC Cellphone Charger (DUT)
•
USB cable
•
4mm Safety Leads
•
AC Source (Optional)
•
BB1000 Break Out Box
Figure 4-4.
Full compliance
IEC 62301 Standby
power test.