PA3000 Four-channel, Multi-phase AC/DC Power Analyzer
Efficiency Testing Single Phase Applications
DEMONSTRATION GUIDE
Custom Limits. Custom limits can also be set with any of the measurement parameters.
Custom limits help set limits based on various standards or test specifications.
Figure 1-8.
Custom limits.
• To set custom limits, either right-click the desired measurement parameter or click the Limits
Setup icon on the menu bar. Stop the measurement update to set up custom limits.
• Custom limits will appear as a separate tab on the measurement grid. The result column will
display red fonts if the limits are failing. Hovering over the results will display the limit function,
limit value, and relative value.
2380 Electronic Load Programming. The ‘List’ mode on 2380 Electronic Load can
be used to automate efficiency testing.
• The load can be set up to automatically step through a set of different load values.
The load can be programmed to execute the list with a fixed time at each step.
• Alternatively, the load can be triggered via a hardware, external trigger or a command
from a controller.
• For more information on how to setup list mode on 2380 Electronic Load, refer to the
product user manual (Document no: 2380-120-60-901-01 Rev. A)