![Tektronix MTS4EAV7 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/tektronix/mts4eav7/mts4eav7_tutorial_1078061028.webp)
Tutorial 3: MPEG-4 compliance
Figure 24: Frames 35, 36 and 37
Conclusion
This tutorial demonstrated how to:
Use and interpret the alert pop-up messages.
Use the Video summary tooltip and understand the information provided.
Use the MacroBlock overlays: MB types and motion vectors.
Use the hexview bitstream viewer.
Additional information
covered
It appears that the encoder chooses MB types less than optimally by using intra
MBs for the background, which wastes many bits.
Consider whether there are software bugs, such that the encoder is too
sensitive to minor changes in the gray level.
Check the encoder part of the codec that decides when to use Intra MBs and
Inter MBs, and when to not code the MB.
Fixing this problem would save many wasted data bits.
NOTE.
The MPEG-4 standard provides more data bits for intensity-gray level
than for color information, so it is naturally more sensitive to changes in gray
level (this mimics the human visual system). However, it appears that the
sensitivity to gray in this example is too great.
22
MTS4EAV7 HEVC / AVC Video and Compressed Audio Analyzer Tutorials