![Tektronix MTS4EAV7 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/tektronix/mts4eav7/mts4eav7_tutorial_1078061017.webp)
Tutorial 2: H.263 compliance and motion vectors
Skip this Warning only in the future
- elects to skip this particular
warning in the future (recommended).
Skip ALL Warning alerts in the future
- elects to skip this alert and
all other alerts in the future.
3.
Select
Skip this Warning only in the future
, and then click
Continue
.
4.
Click the
toolbar icon or type
CTRL
+
P
to resume playing the video.
Another error message appears. (See Figure 10.)
5.
View the error information provided, which indicates a more serious error that
occurs at bitstream byte address 0x0c9cfa, bit 3, after frame 326.
Figure 10: Initial error message
6.
Click
Continue
. Another error message will appear. (See Figure 11.)
7.
Note that it was an MBCPC error that resulted in the Out of Sync alert
message. This often occurs when one syntax error triggers a series of alerts.
MTS4EAV7 HEVC / AVC Video and Compressed Audio Analyzer Tutorials
11