Application Examples
The Tests tab views are displayed. The
navigation view is expanded to show the
failed test. The detail view shows any
PIDs associated with the highlighted test
(none in this example) and the event
log
fi
ltered to show only events for the
highlighted test.
Examine the log entries for error
information. Note that the error reports
refer to a duration of 525 ms. This is
the PMT section repetition rate; 525 ms
was the value set in the example stream
created earlier.
6.
In the navigation view, highlight the
1.5 PMT (Timer) test and select
Edit
Parameters
from the context menu.
7.
In the Edit Parameters dialog box, note
that for this stream the PMT section
maximum repetition interval is set
to 500 ms. Since the repetition rate
found in this stream exceeds this value
(525 ms), it is being reported as an error.
However, by examining the maximum
and minimum repetition rates shown in
the Edit Parameters dialog box (hover
the mouse pointer over the value
fi
eld
and refer to the tootip), you can see that
the rate of 525 ms is within the range
recommended by the DVB standard,
40 ms to 25000 ms.
MTS400 Series Quick Start User Manual
65
Содержание MTS400 Series
Страница 1: ...x MTS400 Series MPEG Test Systems ZZZ Quick Start User Manual P071260701 071 2607 01 ...
Страница 2: ......
Страница 3: ...MTS400 Series MPEG Test Systems ZZZ Quick Start User Manual xx www tektronix com 071 2607 01 ...
Страница 10: ......
Страница 12: ...Table of Contents ii MTS400 Series Quick Start User Manual ...
Страница 22: ...Preface xii MTS400 Series Quick Start User Manual ...
Страница 94: ...User Maintenance 72 MTS400 Series Quick Start User Manual ...