Command Syntax
Table 2-2: Command message elements
Symbol
Meaning
<Header>
This is the basic command name. If the header ends with a question
mark, the command is a query. The header may begin with a colon
(:) character. If the command is concatenated with other commands,
the beginning colon is required. Never use the beginning colon with
command headers beginning with a star (*).
<Mnemonic>
This is a header subfunction. Some command headers have only one
mnemonic. If a command header has multiple mnemonics, a colon (:)
character always separates them from each other.
<Argument>
This is a quantity, quality, restriction, or limit associated with the header.
Some commands have no arguments while others have multiple
arguments. A <space> separates arguments from the header. A
<comma> separates arguments from each other.
<Comma>
A single comma is used between arguments of multiple-argument
commands. Optionally, there may be white space characters before
and after the comma.
<Space>
A white space character is used between a command header and the
related argument. Optionally, a white space may consist of multiple
white space characters.
Commands
Commands cause the instrument to perform a speci
fi
c function or change one of
the settings. Commands have the structure:
[:]<Header>[<Space><Argument>[<Comma> <Argument>]...]
A command header consists of one or more mnemonics arranged in a hierarchical
or tree structure. The
fi
rst mnemonic is the base or root of the tree and each
subsequent mnemonic is a level or branch off the previous one. Commands at a
higher level in the tree may affect those at a lower level. The leading colon (:)
always returns you to the base of the command tree.
Queries
Queries cause the instrument to return status or setting information. Queries
have the structure:
[:]<Header>
[:]<Header>[<Space><Argument> [<Comma><Argument>]...]
You can specify a query command at any level within the command tree unless
otherwise noted. These branch queries return information about all the mnemonics
below the speci
fi
ed branch or level.
Clearing the Instrument
You can clear the Output Queue and reset the instrument to accept a new command
or query by using the selected Device Clear (DCL) function.
2-2
FCA3000, FCA3100, MCA3000 Series Programmer Manual
Содержание FCA3000 Series
Страница 2: ......
Страница 8: ...Preface iv FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Страница 9: ...Getting Started ...
Страница 10: ......
Страница 14: ...Using the USB Interface 1 4 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Страница 15: ...Syntax and Commands ...
Страница 16: ......
Страница 26: ...Command Syntax 2 10 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Страница 135: ...Status and Events ...
Страница 136: ......
Страница 156: ...Status and Events 3 20 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Страница 157: ...Programming Examples ...
Страница 158: ......
Страница 179: ...Appendices ...
Страница 180: ......
Страница 181: ...Appendix A Character Set FCA3000 FCA3100 MCA3000 Series Programmer Manual A 1 ...
Страница 182: ...Appendix A Character Set A 2 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...
Страница 188: ...Appendix D Reserved Words D 2 FCA3000 FCA3100 MCA3000 Series Programmer Manual ...