
Operating basics
Arbitrary Waveform Edit
Example 1
The following example shows how to use the Line edit function. Paste a ramp
waveform before sine waveform:
1.
Select Number of
Points to set the
number of waveform
points to 1000 points.
2.
Select New and then
select Sine. Save this
waveform to User1.
3.
Next, create a 500
point ramp waveform.
4.
Select Operation and
select Line. Do the
following line edit:
X1: 1, Y1: 8191
X2: 250, Y2: 16382
Push Execute. Once
again, select Line from
Operation and perform
the following line edit:
X1: 251, Y1: 16382
X2: 500, Y2: 8191
5.
Push Execute. Save
this waveform to
User2.
6.
Next, paste a
waveform. Push Read
from... and select
User1.
7.
Push Paste at
Beginning. Select
User2 waveform and
then select Paste.
8.
The waveform shown
here is created.
AFG3000 and AFG3000C Series User Manual
51
Содержание AFG3000 Series
Страница 2: ......
Страница 3: ...AFG3000 and AFG3000C Series Arbitrary Function Generators ZZZ User Manual xx...
Страница 6: ......
Страница 9: ...List of Figures Figure 1 Fuse and fuse adapter 13 AFG3000 and AFG3000C Series User Manual iii...
Страница 12: ...Environmental Considerations vi AFG3000 and AFG3000C Series User Manual...
Страница 104: ...Operating basics 90 AFG3000 and AFG3000C Series User Manual...
Страница 110: ...Application Examples 96 AFG3000 and AFG3000C Series User Manual...