TABLE 2 Icont)
Characteristic
Performance Requirement
Supplemental Information
Maximum Safe Input Voltage
at DMM INPUT Connector (cont)
ACV FUNCTION Setting
700 V rms if sinusoidal.
±1000 V (dc + peak ac) between HI
and LO inputs or between HI and
chassis.
±500 V |dc component) between HI
and LO inputs.
k-Q FUNCTION Setting
±100 V (dc + peak ac) between HI
and LO inputs.
LO Floating Voltage
+500 V (dc + peak ac) between LO
and chassis.
INTERNAL BATTERY SUPPLY
Operating Time
Oscilloscope only operating
Calibrator waveform displayed
5.4H.
@
305 Operators
43