Section 4— 2213A Operators
OPERATING PROCEDURES
BASIC APPLICATIONS
INTRODUCTION
After becoming familiar with the capabilities of the 2213A
Oscilloscope an operator can then easily develop conve
nient methods for making particular measurements. The in
formation in this section is designed to enhance operator
understanding and to assist in developing efficient tech
niques for making specific measurements. Recommended
methods for making basic measurements with your instru
ment are described in the procedures contained in this
section.
When a procedure first calls for presetting instrument
controls and obtaining a baseline trace, refer to the “Oper
ator’s Adjustments" part in Section 3 and perform steps 1
through 4 under “Baseline Trace” .
INDEX TO BASIC
APPLICATION PROCEDURES
VOLTAGE MEASUREMENTS ................................
4-1
AC Peak-to-Peak Voltage ..................................
4-1
Instantaneous Voltage ........................................
4-2
Algebraic A dd itio n .................................................
4-3
Common-Mode R ejection....................................
4-3
Amplitude Comparison ........................................
4-4
TIME MEASUREMENTS ........................................
4-4
Time D u ra tio n .......................................................
4-4
Frequency.............................................................
4-5
Rise Time .............................................................
4-5
Time Difference Between Pulses On Time
Related S ignals.....................................................
4-6
Phase Difference ................................................
4-7
TELEVISION DISPLAYS..........................................
4-8
TV Line Signal ........
4-8
TV Field Signal .....................................................
4-8
DELAYED-SWEEP MAGNIFICATION......................
4-9
VOLTAGE MEASUREMENTS
AC Peak-to-Peak Voltage
To make a peak-to-peak voltage measurement, use the
following procedure:
NOTE
This procedure may also be used to make voltage
measurements between any two points on the
waveform.
1.
Preset instrument controls and obtain a baseline
trace.
2.
Apply the ac signal to either vertical-channel input
connector and set the VERTICAL MODE switch to display
the channel used.
3.
Set the appropriate VOLTS/DIV switch to display
about five divisions of the waveform, ensuring that the
VOLTS/DIV Variable control is in the CAL detent.
4.
Adjust the TRIGGER LEVEL control to obtain a stable
display.
5.
Set the SEC/DIV switch to a position that displays
several cycles of the waveform.
6.
Vertically position the display so that the negative
peak of the waveform coincides with one of the horizontal
graticule lines (see Figure 4-1, Point A).
7.
Horizontally position the display so that one of the
positive peaks coincides with the center vertical graticule
line (see Figure 4-1, Point B).
8.
Measure the vertical deflection from peak-to-peak
(see Figure 4-1, Point A to Point B).
4-1
Содержание 2213A
Страница 1: ...Tektronix 2213A OSCILLOSCOPE OPERATORS INSTRUCTION MANUAL ...
Страница 5: ...2213A Operators The 2213A Oscilloscope IV ...
Страница 13: ...General Information 2213A Operators 1 8 ADD DEC 1983 Figure 1 2 Physical dimensions of the 2213A Oscilloscope ...
Страница 36: ...2213A Operators Ifektronix COMMITTED TO EXCELLENCE b I Copyright 1983 Tektronix Inc All rights reserved ...
Страница 37: ......