Operator Troubleshooting
D–8
1503C MTDR User Manual
1.0
INCHES
CENTIMETERS
ONE–WAY DISTANCE
TO OR BETWEEN FAULT, SPLICE,
CONNECTOR, LOAD, END, OR OTHER
IMPEDANCE DISCONTINUITY
.6
.7 .8
1.5
2.0
3
4
Distance is
3.0 cm or 1.18 inches
Dieletric is Air
Time = 200 ps
Velocity Factor = 1
DIELECTRIC
CONSTANT
ROUND
TRIP
TIME
VELOCITY
FACTOR
1.0 1.5 2.0
3 4 5 6
1.0
.8 .7
.6
.5
.4
00ps
150ps
200ps
300ps
500ps
800
Figure D–7: Dielectric Constant and Velocity Factor, Short Distance
The round trip time should be located on the sliding scale that is above the INCHES
and CENTIMETERS scale. Place the point on the sliding scale next to a point on
one of the stationary scales that corresponds to the value of the dielectric constant
or velocity factor. Then read the distance on the INCHES and CENTIMETERS
scale.
If the distance to or between faults is known and you want to find the time or velocity
factor, set the distance under the appropriate arrow first, then read the answer on the
ROUND TRIP TIME scales.
Time vs. Long Distances, in Meters or Feet
(any dielectric)
Distances to or between discontinuities farther apart than about three meters (10
feet) can be found on the METERS and FEET scale. Use the sliding ROUND TRIP
TIME scale just below it and follow the same procedure as above.
METERS
FEET
ONE–WAY DISTANCE
TO OR BETWEEN FAULT, SPLICE,
CONNECTOR, LOAD, END, OR OTHER
IMPEDANCE DISCONTINUITY
20
30
40
50
60 70 80
DIELECTRIC
CONSTANT
ROUND
TRIP
TIME
VELOCITY
FACTOR
1.0 1.5 2.0
3 4 5 6
1.0
.8 .7
.6
.5
.4
00ns
150ns
200ns
300ns
500ns
700n
Dieletric is Solid
Time = 300 ns
Velocity Factor = .66
Distance is
30 m or 99 ft
Polyethylene
100
15
Figure D–8: Dielectric Constant and Velocity Factor, Long Distance