background image

IL603 Tek-SELECT

®

II Manual  • Page 5

2.1 Master Station

Call another station:

1. If the 

TALK

 light is not illuminated red, select the desired

station by pressing its associated selector button. The
following will occur:

a. The 

TALK

 light will illuminate yellow.

b. The selected station 

CALL

 light will illuminate red.

c. If the called station is non-private, sound from the

called station will be heard.

d. Set volume as needed.

Note: If a station button is pressed while the 

TALK

 light

is red, the called station will not be connected. Press
the selector button again to release it, and wait until the

TALK

 light goes out. If the station is left selected, it will

be connected when the system is free, but this may
result in an undesirable howling noise if more than one
master was waiting for the system to be free.

2. Press the 

TALK

 button to speak, release to listen.

3. When finished, press the selected station button again

to extinguish the 

CALL

 and 

TALK

 lights.

Answer a call from a master at a remote:

1. The incoming call will be announced by a chime or tone,

and by a green 

CALL

 light.

2. If the 

TALK

 light is not illuminated red, press the selector

button associated with the illuminated 

CALL

 light. The

following will occur:

a. The 

TALK

 light will illuminate yellow.

b. The selected station 

CALL

 light will change from green

to red.

c. If the called station is non-private, sound from the

calling station will be heard.

Note: If the station button is pressed while the 

TALK

light is red, the selected station will not be connected.
Press the selector button again to release it, and wait
until the 

TALK

 light goes out.

3. Press the 

TALK

 button to speak, release to listen.

4. When finished, press the selected station button again

to extinguish the 

CALL

 and 

TALK

 lights.

Answer a call from a master at a master:

1. Calls from masters are not indicated by a light, but may

be preceded by a short tone signal. Master calls are
announced by voice.

2. To answer:

a. If the 

PRIVACY

 light is illuminated, press the 

PRIVACY

button to turn privacy off.

b. It is not necessary to operate any other controls.

Reply by voice.

Open the door (if installed):

1. Press the 

DOOR

 button (identified by a key).

Page all stations (if installed):

1. If the 

TALK

 light is not illuminated red, press the 

PAGE

switch to the right. The following will occur:

a. The 

TALK

 light will illuminate yellow.

b. The 

PAGE

 light will illuminate yellow.

c. If “talk back” is enabled, sounds from called stations

will be heard.

2. When finished, press the 

PAGE

 switch to the left to

extinguish the 

TALK

 and 

PAGE

 lights.

Monitor a room:

1. If the 

MONITOR

 light is not illuminated red, press the

MONITOR

 button, and then press the button associated

with the desired station. The following will occur:

a. The 

MONITOR

 light will illuminate yellow.

b. The 

MONITOR

 light associated with the selected station

will illuminate red.

c. If the monitored station is non-private, sounds from

that station will be heard.

d. Set volume as needed.

2. When the intercom is in use by another station, the

monitoring will be interrupted, but will return when the
other station is finished.

3. When finished monitoring, press the selected station

button and the 

MONITOR

 button to extinguish the 

MONITOR

and 

CALL

 lights.

Note: Do not attempt to use the 

MONITOR

 function if the

MONITOR

 light is red. To do so may result in a loud noise

from the intercom.

2.2 Remote Station

Call a master:

1. If only one 

CALL

 button is available, press the button. If

there is more than one 

CALL

 button, press the button to

call the desired master.

2. If the remote has a 

PRIVACY

 switch, and if privacy is

selected, press the 

PRIVACY

 button to turn the privacy

OFF.

3. Reply by voice when spoken to.

Section 2.0 — OPERATING INSTRUCTIONS

Содержание Tek-SELECT II SM401

Страница 1: ...unication is needed Multicolored signal lights hands free reply privacy and monitoring are all standard features Optional equipment is available to call all stations distribute music and control remot...

Страница 2: ...raciesthatmayappearinthis documentation TekTone the TekTone logo Tek Call Tek Care Tek Check In Tek Com Tek Digicare Tek Door Tek Entry III Tek Guard Tek Micro Tek MMARS II Tek NIOS Tek Paging Tek Pho...

Страница 3: ...ume Adjustment 3 1 9 Terminal Reference for Master 3 2 0 OPERATING INSTRUCTIONS 2 1 Master Station 5 Call another station 5 Answer a call from a master at a remote 5 Answer a call from a master at a m...

Страница 4: ...strike RY400 Remote control relay 3 outputs RY401 All call relay for 12 stations RY402 In use adapter SB205A Paging horn requires EC105 capacitor and transformer SF400 Call button for use with paging...

Страница 5: ...cal power Locate the transformer within 50 feet 15 meters of the power supply and at least 3 feet 1 meter from master stations remote stations and intercom wiring Do not locate transformers near any s...

Страница 6: ...any part of the system to AC power lines Do not connect transformer to power source until wiring is complete 1 6 Equipment Installation Surface Mounting SM404 SM406 and SM411 Masters 1 Install IH401...

Страница 7: ...400 remote control relay is installed Violet F When this line is shorted to the N connection through a dry contact the master switches from listen to talk A selector button must be pushed in for this...

Страница 8: ...Page 4 IL603 Tek SELECT II Manual...

Страница 9: ...lights Answer a call from a master at a master 1 Calls from masters are not indicated by a light but may be preceded by a short tone signal Master calls are announced by voice 2 To answer a If the PR...

Страница 10: ...Page 6 IL603 Tek SELECT II Manual...

Страница 11: ...IME DIP SWITCH DETAIL 6 OFF ON 1 3 CONNECTOR 2 5 4 1 2 9 11 7 6 8 O R A N G E BLUE G R E E N B R O W N R E D 3 B L A C K B R O W N W H I T E RED WHITE VIOLET WHITE GREY 10 CONNECTOR 1 D N B A P M L X...

Страница 12: ...9 8 11 7 M X 5 6 10 1 3 2 4 MASTER SM411 T1 D2 T2 R2 D1 L N P M E1 E2 R1 D C POWER SUPPLY PK400 F R N C L P D B A X 9 11 7 M 8 5 6 10 1 3 2 4 MASTER SM411 F R N C L P D B A 10 9 11 7 M 8 5 6 X 1 3 2 4...

Страница 13: ...6 C R L SM406 MASTER C X OUTDOOR REMOTE OR642 OR642W TRANSFORMER SS106 24 V A C FOOT SWITCH 7 If the paging horn is not connected to the all call relay the 25V audio transformer is not needed NOTES 2...

Страница 14: ...EMOTE D2 D1 R2 T2 T1 M L E1 C P D R1 N E2 POWER SUPPLY PK400 A P B C R L N D F K2 3 K6 M X 1 K1 K3 K4 K5 4 6 2 5 MASTER SM406 TRANSFORMER SS106 TRANSFORMER SS106 24 V A C X3 K2 K3 K1 S3 S2 X2 X1 ADAPT...

Страница 15: ...ease is not used delete connections to terminals D and D1 5 RY402 should always have a direct connection to the PK400 s N terminal 2 Connect power transformers to 115 V A C in accord with local electr...

Страница 16: ......

Отзывы: