Page 8 • IL603 Tek-SELECT
®
II Manual
X
D
P
1
A
L
R
M
C
N
B
MASTER
S M 4 0 1
X
D
P
1
A
L
R
M
C
N
B
MASTER
S M 4 0 1
X
D
P
1
A
L
R
M
C
N
B
MASTER
S M 4 0 1
X
D
P
1
A
L
R
M
C
N
B
MASTER
S M 4 0 1
4
1
S
3
2
T
E K 7 1 4
MUSIC SYSTEM
X
C
I R 1 0 0 B
REMOTE
INDOOR
TRANSFORMER
S S 1 0 2 A
16 V.A.C.
L
C
D
F
R
B
P
N
A
4
8
9
11
10
1
3
6
2
X
5
7
M
S M 4 1 1
MASTER
L
C
D
F
R
B
P
N
A
3
8
9
11
10
1
X
6
2
4
5
7
M
S M 4 1 1
MASTER
RELEASE
P O 0 0 1
DOOR
9
2
8
7
6
10
5
11
3
4
12
1
P
A
N
B
ALL CALL
R Y 4 0 1
RELAY
L
C
D
F
R
B
P
N
A
5
8
9
11
10
1
3
6
2
4
X
7
M
S M 4 1 1
MASTER
D1
R2
D2
T1
T2
N
R1
L
E2
E1
M
D
P
C
POWER SUPPLY
P K 4 0 0
TRANSFORMER
S S 1 0 6
24 V.A.C.
TRANSFORMER
S S 1 0 6
C
X
REMOTE
INDOOR
I R 1 4 1
C
X
REMOTE
INDOOR
I R 1 4 1
C
X
OUTDOOR
REMOTE
O R 6 1 0
C
X
OUTDOOR
REMOTE
O R 6 4 2
3. For wire size and maximum length, see the installation instructions.
NOTES:
7. The IR100B station receives music but cannot make or receive intercom calls.
4. If lighted outdoor remotes are not used, terminals E1 and E2 do not need to be used.
6. If the door release is not used, delete wires to terminals D, and D1.
5. If the music system is not used, delete wires to terminals R, R1 and R2.
1. Actual terminal locations not shown. See terminal identification diagrams.
2. Connect power transformers to 115 V.A.C. in accord with local electrical codes.
P
1
A
N
B
9
11
4
2
3
8
10
12
6
5
7
ALL CALL
RY401
RELAY
F
R
N
C
L
P
D
B
A
9
8
11
X
M
7
5
6
10
1
3
2
4
MASTER
SM411
F
R
N
C
L
P
D
B
A
9
8
11
7
M
X
5
6
10
1
3
2
4
MASTER
SM411
T1
D2
T2
R2
D1
L
N
P
M
E1
E2
R1
D
C
POWER SUPPLY
PK400
F
R
N
C
L
P
D
B
A
X
9
11
7
M
8
5
6
10
1
3
2
4
MASTER
SM411
F
R
N
C
L
P
D
B
A
10
9
11
7
M
8
5
6
X
1
3
2
4
MASTER
SM411
F
R
N
C
L
P
D
B
A
9
X
11
7
M
8
5
6
10
1
3
2
4
MASTER
SM411
TRANSFORMER
SS102A
16 V.A.C.
4
1
S
3
2
T
EK714AW
MUSIC SYSTEM
TRANSFORMER
SS106
F
R
N
C
L
P
D
B
A
9
8
11
6
M
7
4
5
10
1
2
X
3
MASTER
SM411
F
R
N
C
L
P
D
B
A
9
8
11
6
M
7
4
5
10
1
X
2
3
MASTER
SM411
C
X
OUTDOOR
OR642
REMOTE
F
R
N
C
L
P
D
B
A
9
8
11
6
M
7
4
5
10
X
2
1
3
MASTER
SM411
F
R
N
C
L
P
D
B
A
9
8
11
6
M
7
X
5
10
1
3
2
4
MASTER
SM411
F
R
N
C
L
P
D
B
A
9
8
11
6
M
7
5
X
10
1
3
2
4
MASTER
SM411
F
R
N
C
L
P
D
B
A
9
8
11
6
M
7
4
5
10
1
3
2
X
MASTER
SM411
RELEASE
PO001
DOOR
TRANSFORMER
SS106
24 V.A.C.
NOTES:
7. If a lighted outdoor remote is not used, connect terminal X directly to the SM411 (terminal 11
to the RY401 all call relay ( note OR641 remote, connected to terminal 11, in the above diagram).
6. If any station should not receive all call, do not connect the X terminal for that station
2. Connect power transformers to 115 V.A.C. in accord with local electrical codes.
5. If the door release is not used, delete wires to terminals D, and D1.
in the above diagram), and do not use PK400 terminals E1 and E2.
4. If the music system is not used, delete wires to terminals R, R1 and R2.
1. Actual terminal locations not shown. See terminal identification diagrams.
3. For wire size and maximum length, see the installation instructions.
Figure 6 — SM411 Master to Master
Wiring Diagram
Figure 7 — SM411 Intermix
Wiring Diagram
Содержание Tek-SELECT II SM401
Страница 8: ...Page 4 IL603 Tek SELECT II Manual...
Страница 10: ...Page 6 IL603 Tek SELECT II Manual...
Страница 16: ......