Kona Home Sensor TRM
T0005370_TRM
Version Rev-C 1.0
TEKTELIC Communications Inc.
Confidential
Page 22 of 34
Powered Off
Sample Rate
0x01 (1 Hz)
3.4.3.8
Example DL Messages
In the following example payloads, the Command Field is boldfaced:
•
Set Impact Threshold and Impact Debounce Time:
o
DL payload: { 0x
B1
00 C8
B3
00 0A }
▪
Reg 31 and Reg 33 with their write bits set to true
▪
Impact Threshold set to
2000
milli-
𝑔
and Impact Debounce Time set to
10 seconds.
•
Set Sample Rate and read it back:
o
DL payload: { 0x
B5
06
35
}
▪
Reg 35 with write bit set to true
▪
Reg 35 with write bit set to false
▪
Sample rate set to 200 Hz, and then read back
•
Power on the transducer with Impact Threshold enabled but Break-In Threshold
disabled, and set
‘Magnitude’ as the Value to Transmit
:
o
DL payload: { 0x
B4
82
B2
02 }
▪
Reg 34 and Reg 32 with their write bits set to true