Kona Home Sensor TRM
T0005370_TRM
Version Rev-C 1.0
TEKTELIC Communications Inc.
Confidential
Page 11 of 34
Impact Alarm
0x0C
0x00
1
Digital
0x00: No impact alarm
0xFF: Impact alarm
Motion Event Count 0x0D
0x04
2
Counter
Number (MSB first)
2.1
Example UL Payloads
In the following example payloads, the data channel ID and data type ID are boldfaced:
•
0x
03 67
00 0A
04 68
28
o
0x 𝟎𝟑 𝟔𝟕 (Temperature) = (0x 00 0A) × 0.1°C = 1°C
o
0x 𝟎𝟒 𝟔𝟖 (RH) = (0x 28) × 0.5% = 20%
•
0x
04 68
14
01 00
FF
08 04
00 05
o
0x 𝟎𝟒 𝟔𝟖 (RH) = (0x 14) × 0.5% = 10%
o
0x 𝟎𝟏 𝟎𝟎 (Input) = 0x FF = High
o
0x 𝟎𝟖 𝟎𝟒 (Input Count) = 0x 00 05 = 5
switch triggers
•
0x
04 68
2A
03 67
FF FF
00 FF
01 2C
o
0x 𝟎𝟒 𝟔𝟖 (RH) = (0x 2A) × 0.5% = 21%
o
0x 𝟎𝟑 𝟔𝟕 (Temperature) = (0x FF FF) × 0.1°C = −0.1°C
o
0x 𝟎𝟎 𝐅𝐅 (Battery Voltage) = (0x 01 2C) × 0.01 V = 3.00 V
•
0x
02 00
FF
07 71
00 3A 00 07 00 53
01 00
FF
o
0x 𝟎𝟐 𝟎𝟎 (Light Detected) = 0x FF = Bright
o
0x 𝟎𝟕 𝟕𝟏 (Accelerometer Data) = [Xaxis: (0x 00 3A) × 0.01𝑔, Yaxis: (0x 00 07) ×
0.01𝑔, Zaxis: (0x 00 53) × 0.01𝑔] = [Xaxis: 0.58𝑔, Yaxis: 0.07𝑔, Zaxis: 0.83𝑔]
o
0x 𝟎𝟏 𝟎𝟎 (Input) = 0x FF = High
•
0x
0D 04
00 02
06 00
FF
o
0x 𝟎𝐃 𝟎𝟒 (Motion Event Count) = 0x 00 02 = 2
motion events
o
0x 𝟎𝟔 𝟎𝟎 (Breakin) = 0x FF =
break-in detected