TekSmart Fitness Contour Скачать руководство пользователя страница 9

7

Inserting/Changing the Batteries

1.  Open the battery compartment at the back of the device by pushing the battery  

 

  cover labeled “Open” downward (this area features  

 

  raised marks for easy identification).

2.  Insert 3 AAA (1.5 V) batteries in the 

 

  battery compartment; make sure to match 

  up the symbols (+/–).

3.  Close the battery cover by carefully placing the   

  stud into the slot in the rear area and  

  sliding it upward, applying slight pressure.

4.  Follow the same procedure when replacing the batteries as needed.

  Always read and follow the specific instructions of the battery manufacturers.

Note:

 Always use only 3x1.5V(AAA) batteries.

•  Keep away from children.

•  Do not recharge.

•  Do not short-circuit.

•  Do not throw into a fire.

•  Please recycle. Do not dispose of old batteries with your household waste; dispose of   

them safely at your recycling centre or business where the batteries were purchased.

Preparing the Skin for a Session

Proper preparation of the skin covered by the electrodes allows more stimulation to reach 

targeted tissues, prolongs electrode life, and reduces the risk of skin irritation. Wash the area 

with mild soap and water (don't use alcohol). Rinse and dry thoroughly.

Make sure that your skin is clean and free of oil

Setting-up the Shorts

1. Turn the short inside out and lay on a flat surface.

2. Bend the electrode slightly and insert into the pockets with the gray side down and black  

  side up. Insert one electrode in each of the electrode holders,sliding the electrode under the  

  pocket lip.

3. Insert pin-end of the four lead-wires through the eyelet hole on the outside of the 

  shorts. This can be done on the left-side or right-side depending on which pocket you

  prefer to put the device in during your session.

4.  Slide one Blue tip wire over and out of the upper right eyelet hole. Slide the other Blue tip   

  wire down and out of the lower right eyelet hole. Slide one Black tip wire out of the  

  upper left eyelet hole. Slide the other Black tip wire down and out of the lower left  

  eyelet hole.

5. Insert the pin-end of the lead-wire snugly into the electrode. Repeat for all wires. 

  Make sure the wires are completely inserted into the electrode. 

6. Apply a small ( dime size) amount of the conductive gel on the electrodes with your    

  finger, smear the gel around covering entire surface of the electrode.

7.  Turn the short right side out and slide onto your body, pulling them up from the waistband.  

  Try to keep the electrodes away from contacting your gluteus until the shorts are 

  completely on. (In the event that some gel gets on your leg in the process of pulling the  

  shorts up, simply wipe it off with a cloth.)

The electrodes will need to be touching your bare skin in order to create a contraction. You may 

want to wear a thong if you do not feel comfortable wearing the compression shorts without 

undergarments. You might need to adjust the position of the garments slightly until you find 

the most comfortable position. However the positioning will become much easier after a few 

sessions. For reasons of Hygiene, please do not share Well Life Buttock Muscle Stimulator and 

its accessories with others, for single person use only !

Содержание Contour

Страница 1: ......

Страница 2: ...Turning OFF the Device 8 Selecting the Program 9 Selecting the Exercise Intensity Level 9 SPECIAL FEATURES 10 CARE AND MAINTENANCE 11 TROUBLESHOOTING 13 WL 2413B STIMULATOR TECHNICAL SPECIFICATIONS 13 Warranty 14 Please read this Use and Care Manual carefully before you start using your TekSmart EMS Device Careful reading of the contraindications warnings precautions adverse reactions caution with...

Страница 3: ...s has not been established You suffer from cancer The effects of electronic stimulation on cancerous tissue are unknown You are under medical supervision for cognitive dysfunction as you may not be able to comply with safety instructions The unit is in close proximity to shortwave or microwave diathermy equipment or you are connected to high frequency surgical equipment because of risk of device i...

Страница 4: ...Do not use this system while sleeping Do not use if you feel numbness Do not use this system in or close to water Do not use the pads over or close to cancerous lesions Do not use the device in the following circumstances when there is a tendency to bleed internally following an injury of fracture following recent surgical procedures when stimulation may disrupt the healing process over areas of s...

Страница 5: ...rience skin irritation or hypersensitivity due to the electrical stimulation or the conductive medium Keep the stimulator out of the reach of children Application of moderate heat thermal wrap to muscles as well as moistening skin prior to treatment improves treatment efficacy use of cold packs on treated muscles after treatment is likewise recommended This unit should only be used with the leads ...

Страница 6: ...red as skin irritation and it will normally disappear within 30 minutes after the electrodes are removed If the redness does not disappear after 30 minutes from the removal of electrodes do not use the stimulator again until after the excessive redness has disappeared Turn off the stimulator if the stimulation feels unpleasant or does not provide pain relief Keep your system out of the reach of ch...

Страница 7: ... your eyes and to your head and face You should stop using the device and should consult with your physician if you experience adverse reactions from the device Conditions that may affect your TekSmart EMS System Since the stimulator is a battery operated electronic system its output performance and safety may be affected greatly in extreme humidity Therefore it is very important to keep the stimu...

Страница 8: ... 7 Time remaining 8 CH1 intensity level 9 CH2 intensity level 10 Lock status indicator 11 Battery status indicator 12 Pause indicator 13 Battery compartment 14 Battery cover 88 88 88 Pi8 PAUSE CH1 CH2 MIN MODE CH1 CH2 ON OFF 3 AAA Batteries EMS Device Lead Wires 4 Silicone Electrodes 3 4 oz Tube Conductive Gel Conductive Gel 3 4 oz The Curvassure Butt Toning Shorts ...

Страница 9: ...electrode under the pocket lip 3 Insert pin end of the four lead wires through the eyelet hole on the outside of the shorts This can be done on the left side or right side depending on which pocket you prefer to put the device in during your session 4 Slide one Blue tip wire over and out of the upper right eyelet hole Slide the other Blue tip wire down and out of the lower right eyelet hole Slide ...

Страница 10: ... In an emergency you may also pull the connector wire s from the device Note To prevent unpleasant electric shocks never remove the device while it is still turned on Selecting the Program The Device offers three different preset training programs The programs differ with respect to varying pulse widths frequencies and ON OFF time 1 Press the MODE button The P will be flashing Press ON or OFF repe...

Страница 11: ...intensity level will reset to 0 each time the device turns off including after training sessions or changing the Program during training session Your Contraction Intensity Level For those not familiar with the sensation of ems it can be a little strange As you increase the intensity you will initially feel a tingle in the area under the pads Gradually increase the intensity until you feel your mus...

Страница 12: ...ill flash on the display Press MODE again PAUSE will disappear on the display and session will continue The intensity level will stay at your current setting and time will continue to count down Automatic Shut off The device automatically turns off when no button is pressed for 60 seconds The device automatically turns off when the time for your exercise session has elapsed Intensity Level Reset F...

Страница 13: ...ect the cables from the stimulator when not in use Do not pull on the cables but rather on the plugs attached to the ends of the cables Store the stimulator with the cables in a clean dry place Electrodes The electrode pads are conductive silicone pad reusable for single person use Take off from the garment after each use wipe off and dry the electrodes with a soft cloth dampened with soap and wat...

Страница 14: ...gnetic immunity The device is intended for use in the electromagnetic environment specified below The customer or the user of the device should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood con crete or ...

Страница 15: ...customer service 13 WL 2413B STIMULATOR TECHNICAL SPECIFICATIONS Channel Dual isolated between channels Pulse amplitude Adjustable 0 80mA peak into 500Ω load each channel Pulse Rate As pre programming operation mode Pulse Width As pre programming operation mode Software ramp up feature Pulse width ramp up when change mode Timer 30 minutes LCD Show modes pulse rate pulse width timer CH1 CH2 intensi...

Страница 16: ... to be free from defects in workmanship and materials at the time of delivery The system accessories short and conductive gel for reasons of hygiene they can neither be taken back nor exchanged once used The distributor reserves the right to replace or repair the unit at their discretion HOW TO GET HELP To get assistance or answers to your questions please contact TekSmart Fitness LLC Visit our we...

Отзывы: