BD-1/07-002
10
5.3. Arming/Disarming by a key:
All system or determined partitions are
armed/disarmed by pressing a key or a button which is connected to key input.
5.4. Arming/Disarming by remote controller
This feature requires optional module. If your system
includes
remote
controller
module
you
can
arm/disarm system by your remote controller
5.5. Partial Arming/Disarming*:
Selected partitions are armed/disarmed by partial
arming.
* This feature can not be used in VAP2xx and VAP3xx Alarm Panel.
5.6. One-Touch Arming*:
Selected partitions are armed by pressing to the partition
button (A, B, C, D) without entering code. (You may select more than one partition).
* This feature can not be used in VAP2xx and VAP3xx Alarm Panel.
5.7. Arming/Disarming by Phone*:
Basic arming/disarming can be done by phone.
(See remote control by phone section for details)
* This feature can not be used in VAP2xx and VAP3xx Alarm Panel.
6. AUTOMATIC ARMING/DISARMING
There are two types of automatic arming / disarming as follows.
6.1. Automatic Arming/Disarming on Determined Time
This feature allows you to arm/disarm any partition or all system on determined time
Setting
Address
LCD Menu
Automatic Arming Partitions**
12 01
Panel Settings/Auto Arm/Disarm/Auto Arm Partitions
Automatic Arming Days
12 02
Panel Settings/Auto Arm/Disarm/Auto Arm Days
Automatic Arming Time
12 03
Panel Settings/Auto Arm/Disarm/Auto Arm Time
Automatic Disarming Partitions**
12 04
Panel Settings/Auto Arm/Disarm/Auto Disarm Partitions
Automatic Disarming Days
12 05
Panel Settings/Auto Arm/Disarm/Auto Disarm Days
Automatic Disarming Time
12 06
Panel Settings/Auto Arm/Disarm/Auto Disarm Time
(**)Since there is no partition in VAP2xx and VAP3xx alarm panel, Automatic arming/disarming feature
can be activated by selection of the 1 option in related address.
[Press] short to the partition/partitions buttons (A,B,C,D) you want to arm (you will hear a
short beep and see that pressed buttons will be flashing)
[Enter] your 4 digit user code.
[Enter] to arm, to disarm the system.
[Press] long to the partition/partitions buttons (A,B,C,D) you want to arm
You will hear a long beep and see that pressed buttons will be flashing (After
5 seconds, the partitions you selected will be armed. Press “Exit” key to
cancel the arming.)
Enter to the master program.
[Enter]
(Program) key long until you hear a long beep.
[Enter] your 4 digit master code.
[Enter] the related address or menu according to following table.
Содержание VAP Series
Страница 1: ...VAP Series Alarm System User s Manual Issue Date 13 02 2007 TD 1 07 002 ...
Страница 33: ...BD 1 07 002 32 ...
Страница 34: ...BD 1 07 002 33 ...
Страница 35: ...BD 1 07 002 34 ...
Страница 36: ...BD 1 07 002 35 http www teknim com ...