6. Operating the system
6.1. Explanation of the operating elements
Control functions, setting options for programs, menu navigation, error messages, etc. are
described in the enclosed operating manual of the unit control. There is also an explanation of the
elements of the control panel.
CAUTION
Possibility of hazardous dust accumulation.
The operator has to make sure that the upstream processing machine is NOT put into
operation without the cyclone separator! If a fault is detected at the cyclone separator, the
processing ma-chine has to be switched out immediately.
Operating elements for the device control
Representation Designation
Description / function
Main switch
●
OFF:
The device is disconnected from the power supply.
●
ON:
The device is connected to the power supply and
ready to operate.
The main switch also serves as an emergency
off switch.
ON-OFF-switch
By means of this switch, the device is switched on and off.
When the device is switched off, it is not
disconnected from the power supply.
Button fo manual
water filling
Regardless of the current fluid level, the system can be
filled manually by pressing the button
filling.
This is
however only possible when the suction unit is not
running. The process is started or stopped when the
button is pressed. When the valve is opened, a visual
feedback is given out by the illuminated push button.
Operating elements for status and error messages
Representation Designation
Description / function
Signal horn
Honking signals that the unit signals an error. Please refer to
the error message shown on the display of the control.
BA_Nassabscheider_WNA-AL_211118_EN
14