CONVERSIONS
10) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in question. To do this, first remove the burner tops
using a wrench "B". Now unscrew injector "A" (see
fig. 13) and fit a injector corresponding to the
utilized type of gas in its place.
It is advisable to strongly tighten the injector in
place.
After the injectors have been replaced, the
burners must be regulated as explained in
paragraphs 8. The technician must reset any
seals on the regulating or pre-regulating
devices and affix the label corresponding to the
new gas regulation on the appliance instead of
the already existing one. This label is supplied
in the packet containing the spare injectors.
For the sake of convenience, the nominal rate table
also lists the heat inputs of the burners, the
diameter of the injectors and the working pressures
of the various types of gas.
BURNER ARRANGEMENT ON THE HOT PLATE
FIG. 13
G30 - BUTANE
50
204
72 M
900
2800
41
2
RAPID
G31 - PROPANE
50
200
72 M
900
2800
41
G20 - NATURAL
20
267
117 Y
750
2800
Adj.
G25 - NATURAL
20
310
133 F3
750
2800
Adj.
BURNERS
N°
DESCRIPTION
GAS
NORMAL
PRESSURE
NORMAL
RATE
INJECTOR
DIAMETER
NOMINAL HEAT
INPUT (W)
mbar
g/h
l/h
1/100 mm
Min.
Max. 1/100 mm
G30 - BUTANE
50
73
46 M
500
1000
30
5
AUXILIARY
G31 - PROPANE
50
71
46 M
500
1000
30
G20 - NATURAL
20
95
75 X
400
1000
Adj.
G25 - NATURAL
20
111
78 F1
400
1000
Adj.
BY PASS