background image

19

GB

Dimensions

Hob GKS 290 height/width/depth 

mm 

80 x 290 x 520

Hob GKS 300 height/width/depth 

mm 

80 x 300 x 520

Installation dimensions width / depth 

mm 

270 x 500

Nominal load for all gas types

Flame on high

Back high-speed burner  

2800

Front standard burner:

W

1900

Flame on low

back high-speed burner 

560

Front standard burner:

W

380 

Total nominal heat input 

4700

Total connected load of liquefied petroleum gas 

g/h 

342

Gas supply (thread) 

R ½”

Nominal pressure

Natural gas 

mbar

20

Liquefied petroleum gas

mbar

30 / 50

Electrical connection

Mains voltage 

230V~ , 50 Hz

Appliance category 2/1
Country of destination: GB
Category for GB: II2H3+

 This appliance complies with the following E.E.C regulations:

73/23-90/683 (low voltage regulation);

89/336 (EMC regulations)

- 90/396 (gas regulations)

93/68 (general instruction) and following changes.

Technical data

Table: injector identification

GB-Cat

II2H3+

Flame on high

Flame on low

Burner

Natural gas 

H

20 mbar

Liquefied petroleum 

gas

28-30/37 mbar

Natural gas 

H

20 mbar

Liquefied petroleum 

gas

28-30/37 mbar

A front 

105

70

48

28

B back

132

81

58

39

Содержание GKS 290

Страница 1: ...I S BESZEREL SI UTAS T S Einbau Gas Glaskeramik Kochfeld mit Knebeln Built in gas glass ceramic hob with switches Plaque de cuisson encastrable au gaz en vitroc rame avec manettes Encimera incorporada...

Страница 2: ...leaning and care 15 Cooking zones 15 What to do if trouble occurs 15 Glas ceramics 15 Assembly instructions 16 Safety instructions for the kitchen fitter 16 Factory setting 16 Important note for fitte...

Страница 3: ...essory parts become hot during use Always keep children away from the appliance Always use a cloth or saucepan gloves and handle the saucepans carefully to avoid injury Do not allow the connection cab...

Страница 4: ...faster than thick ones As the heat is not distributed evenly there is a danger that some of the food will overheat Therefore it should be stirred regularly Thick bottomed saucepans reduce the danger...

Страница 5: ...and operating the burners The burners are ignited by an electric spark ignition built into each burner To ignite push the correct control knob in fully and turn it up to full flame The spark ignites...

Страница 6: ...ughly Persistent dirt and caking can best be removed with a glass scraper Take care when using the scraper danger of injury Repairs must be carried out by a qualified expert Incorrect repairs can be e...

Страница 7: ...ce Details on the heat load and the gas flow through the individual burners can be found in the technical data If changing to another gas type the injectors must be replaced Adjusted or replaced parts...

Страница 8: ...t silicone rubber not included in delivery Working surface cut out Cut out the worktop recess accurately with a good straight saw blade or recessing machine The cut edges should then be sealed so that...

Страница 9: ...s and give the user the operating instructions Point out in particular that changes to the construction which restrict the combustion air supply must be followed by a new function check Point out to t...

Страница 10: ...ead R Nominal pressure Natural gas mbar 20 Liquefied petroleum gas mbar 30 50 Electrical connection Mains voltage 230V 50 Hz Appliance category 2 1 Country of destination GB Category for GB II2H3 This...

Страница 11: ...L 55 21 671 01 88 21 772 16 37 TEKA CHILE LTDA Santiago de Chile CHILE 56 2 273 34 68 2 273 10 88 TEKA MEXICANA S A DE C V Mexico D F MEXICO 52 5 762 04 90 5 762 05 17 P T TEKA BUANA Jakarta INDONESIA...

Отзывы: