7) GAS CONNECTION
Before connecting the appliance, check that
the values on the data label affixed to the
underside of the hot plate correspond to those
of the gas and electricity mains in the home.
A label on the appliance indicates the
regulating conditions: type of gas and working
pressure. Gas connection must comply with
the pertinent standards and provisions in force.
When gas is supplied through ducts,
the
appliance must be connected to the gas supply
system:
o with a rigid steel pipe. The joints of this pipe must
consist of threaded fittings conforming to the
standards.
o With copper pipe. The joints of this pipe must
consist of unions with mechanical seals.
o With seamless flexible stainless steel pipe. The
length of this pipe must be 2 meters at most and
the seals must comply with the standards.
When the gas is supplied by a bottle,
the
appliance must be fuelled by a pressure governor
conforming to the provisions in force and must be
connected:
o with a copper pipe. The joints of this pipe must
consist of unions with mechanical seals.
o With seamless flexible stainless steel pipe. The
length of this pipe must be 2 meters at most and the
seals must comply with the standards. It is
advisable to apply the special adapter to the flexible
pipe. This is easily available from the shops and
facilitates connection with the hose nipple of the
pressure governor on the bottle.
In case of liquid bottledgas supply, mount a pressure
governor according to the regulations in force.
To connect the hob with the bottled pressure governor
use a flexible tube 95 cm. lenght fastened by hose
clamp.
This tube must run as shown in fig. 9/A and 9/B in
order to avoid contact with the heating surfaces.
At the connection end, verify the gasproof using a
soap solution, never a flame.
WARNINGS:
remember that the gas inlet union on the
appliance is a 1/2" gas parallel male type in
compliance with ISO 7-1 standards.
Installation of stainless steel pipe and rubber
hose pipe must ensure that it is never able to
touch mobile parts of the built-in cabinet (eg.
drawers). Furthermore, it must not pass
through compartments that could be used for
storage purposes.
When using a rubber hose pipe, it is essential
to comply with the following instructions:
- no part of the pipe must be able to touch
parts the temperature of which exceeds 65K.
- The pipe must not be pulled or twisted,
throttled or tughtly bent.
- It must not come into contact with sharp
edges or corners.
- It must be easy to inspect the entire pipe
length in order to check its state of wear.
- The pipe must be replaced within the date
stamped on the pipe itself.
- The appliance complies with the provisions of
the following EEC Directives:
90/396 + 93/68 regarding gas safety.
INSTRUCTIONS FOR GAS CONNECTION
Once the gas connection elbow has been fitted,
and if you need to remove it or change its
position, it is important to place the gaskets (A)
in-between the elbow (B) and the LPG nipple
(C) before you tighten it.
INSTALLATION