background image

8

7) GAS CONNECTION

Before connecting the appliance, check that

the values on the data label affixed to the

underside of the hot plate correspond to those

of the gas and electricity mains in the home.

A  label  on  the  appliance  indicates  the

regulating conditions: type of gas and working

pressure. Gas connection must comply with

the pertinent standards and provisions in force. 

When gas is supplied through ducts,

the

appliance must be connected to the gas supply

system:

o with a rigid steel pipe. The joints of this pipe must

consist of threaded fittings conforming to the

standards. 

o With copper pipe. The joints of this pipe must

consist of unions with mechanical seals.

o With seamless flexible stainless steel pipe. The

length of this pipe must be 2 meters at most and

the seals must comply with the standards.

When the gas is supplied by a bottle,

the

appliance must be fuelled by a pressure governor

conforming to the provisions in force and must be

connected:

o with a copper pipe. The joints of this pipe must

consist of unions with mechanical seals.

o With seamless flexible stainless steel pipe. The

length of this pipe must be 2 meters at most and the

seals  must  comply  with  the  standards.  It  is

advisable to apply the special adapter to the flexible

pipe. This is easily available from the shops and

facilitates connection with the hose nipple of the

pressure governor on the bottle.

In case of liquid bottledgas supply, mount a pressure

governor according to the regulations in force.

To connect the hob with the bottled pressure governor

use a flexible tube 95 cm. lenght fastened by hose

clamp.

This tube must run as shown in fig. 9/A and 9/B in

order to avoid contact with the heating surfaces.

At the connection end, verify the gasproof using a

soap solution, never a flame.

WARNINGS:

remember that the gas inlet union on the

appliance is a 1/2" gas parallel male type in

compliance with ISO 7-1 standards.

Installation of stainless steel pipe and rubber

hose pipe must ensure that it is never able to

touch mobile parts of the built-in cabinet (eg.

drawers).  Furthermore,  it  must  not  pass

through compartments that could be used for

storage purposes.

When using a rubber hose pipe, it is essential

to comply with the following instructions:

- no part of the pipe must be able to touch

parts the temperature of which exceeds 65K.

- The pipe must not be pulled or twisted,

throttled or tughtly bent.

- It must not come into contact with sharp

edges or corners.

- It must be easy to inspect the entire pipe

length in order to check its state of wear.

- The pipe must be replaced within the date

stamped on the pipe itself.

- The appliance complies with the provisions of

the following EEC Directives:

90/396 + 93/68 regarding gas safety.

INSTRUCTIONS FOR GAS CONNECTION

Once the gas connection elbow has been fitted,

and if you need to remove it or change its

position, it is important to place the gaskets (A)

in-between the elbow (B) and the LPG nipple

(C) before you tighten it.

INSTALLATION

Содержание EX/90 5G AI AL PC CI

Страница 1: ...advice for the maintenance EX 90 3G AI TR EX 90 3G AI AL TR EX 90 4G AI AL EX 90 5G AI AL TR EX 90 5G AI AL TR CI EX 90 5G AI AL PC CI Instructions Manual EX 90 3G AI TR EX 90 3G AI AL TR EX 90 4G AI...

Страница 2: ...ed steel pan support 2F left 11 Central enamelled steel pan support 12 Enamelled steel pan support fish central burner 13 Burner n 1 control knob 14 Burner n 2 control knob 15 Burner n 3 control knob...

Страница 3: ...correctly place In the event of the Burner flames being accidentally extinguished turn off the burner control and do not attempt to re ignite the burner for a least 1 minute HOW TO USE THE BURNERS Be...

Страница 4: ...The room must therefore be well ventilated by keeping the natural air vents clear fig 3 and by activating the mechanical aeration device suction hood or electric fan fig 4 and fig 5 Intensive and len...

Страница 5: ...bodies Check that enamelled burner cap C fig 6 have correctly positioned on the burner head It must be steady The exact position of the pan support is established by the rounded corners which should...

Страница 6: ...surements of the opening made in the top of the modular cabinet and into which the hot plate will be installed are indicated in either fig 7 Always comply with the measurements given for the hole into...

Страница 7: ...stick the plastic laminate to the cabinet must be able to withstand a temperature of not less than 150 C otherwise the laminate could come unstuck The appliance must be installed in compliance with th...

Страница 8: ...bottle In case of liquid bottledgas supply mount a pressure governor according to the regulations in force To connect the hob with the bottled pressure governor use a flexible tube 95 cm lenght fasten...

Страница 9: ...overtemperature of 65K Never use reductions adapters of shunts for connection since these could create false contacts and lead to dangerous overheating The outlet must be accessible after the built i...

Страница 10: ...he provisions established by the provisions governing such appliances 10 FIXING THE HOT PLATE The hot plate has a special seal which prevents liquid from infiltrating into the cabinet Strictly comply...

Страница 11: ...emove knob M fig 14 of the tap which is simply pressed on to its rod Insert a small screwdriver D into hole C fig 14 and turn the throttle screw to the right or left until the burner flame has been ad...

Страница 12: ...abels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate chart also lists the heat inputs of the burners the diameter of t...

Страница 13: ...G30 BUTANE 28 30 127 65 500 1750 35 G20 NATURAL 20 167 97 Z 500 1750 Adj BURNERS N DESCRIPTION GAS NORMAL PRESSURE NORMAL RATE INJECTOR DIAMETER NOMINAL HEAT INPUT W mbar g h l h 1 100 mm MIN MAX 1 1...

Страница 14: ...TOWN GUANGZHOU 20 383 140 1 800 2800 Adj BUTANE 30 127 65 500 1750 32 TOWN SHANGHAI 10 459 200 2 500 1750 Adj TOWN GUANGZHOU 20 223 110 1 500 1750 Adj BURNERS N DESCRIPTION GAS NORMAL PRESSURE NORMAL...

Страница 15: ...ced to ensure a perfect tightness Greasing the taps see fig 20 21 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean th...

Страница 16: ...l for our ambient Always put them in a separate and safe container If you eliminate your appliance remember to take off the battery CAUTION The device should not be operated for more than 15 second If...

Страница 17: ...cable is replaced the installer should leave the ground wire longer than the phase conductors fig 23 and comply with the recommendations given in paragraph 8 Gas hot plate H05 RR F Section 3 x 0 75 m...

Страница 18: ...H BATTERY 5 BURNERS CENTRALUR LPG 28 30 mbar LPG 37 mbar NATURAL 20 mbar Qn LPG Gas Rate 10 40 kW Qn LPG Gas Rate 756 g h Voltage 220 230 V Frequency 50 Hz 3 BURNERS CENTRALUR LPG 28 30 mbar LPG 37 mb...

Страница 19: ...V Frequency 50 Hz 5 BURNERS CENTRALFISH LPG 28 30 mbar NATURAL 20 mbar Qn LPG Gas Rate 10 10 kW Qn LPG Gas Rate 735 g h Voltage 220 230 V Frequency 50 Hz 5 BURNERS CENTRALUR LPG 28 30 mbar NATURAL 20...

Страница 20: ...WN SHANGHAI 10 mbar TOWN GUANGZHOU 20 mbar Qn Town Gas Rate 7 65 kW Qn LPG Gas Rate 8 1 kW Qn LPG Gas Rate 589 g h Voltage 1 5 V DC 5 BURNERS CENTRAL UR LPG 30 mbar TOWN SHANGHAI 10 mbar TOWN GUANGZHO...

Страница 21: ...our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare...

Страница 22: ...62 01 600 3 762 01 626 MALAYSIA Mexico Mexico D F TEKA MEXICANA S A DE C V 52 5 762 04 90 5 762 05 17 Poland Warszawa TEKA POLSKA SP Z O O 48 22 652 18 94 22 850 12 48 Portugal Ilhavo TEKA PORTUGUESA...

Страница 23: ...23...

Страница 24: ...24...

Отзывы: