CONVERSIONS

BURNER ARRANGEMENT ON THE HOT PLATE

CHINA MARKET

BUTANE

30

244                        90                  1400

3350           62

TOWN (SHANGHAI)

10

971

330 3

1400

3100          Adj.

TOWN (GUANGZHOU)

20

472

165 2

1400

3100          Adj.

BUTANE

30

204     

83

800

3000           45

TOWN (SHANGHAI)

10

787

260 3

800

2800          Adj.

TOWN (GUANGZHOU)

20

383

140 1

800

2800          Adj.

BUTANE

30

127  

65

500

1750           32

TOWN (SHANGHAI)

10

459

200 2

500

1750          Adj.

TOWN (GUANGZHOU)           

20  

223

110 1

500

1750          Adj.

BURNERS

DESCRIPTION

GAS

NORMAL

PRESSURE

NORMAL

RATE

INJECTOR

DIAMETER

NOMINAL HEAT

INPUT (W)

mbar

g/h      l/h

1/100 mm               MIN.

MAX.       1/100 mm

1

ULTRA RAPID

2

RAPID

3

SEMIRAPID 

BY

PASS

BUTANE

30

73  

50

400

1000           30

TOWN (SHANGHAI)

10

262

135 11

400

1000          Adj.

TOWN (GUANGZHOU)           

20  

128

87

400

1000          Adj.

4

AUXILIARY 

Содержание EX/90 5G AI AL PC CI

Страница 1: ...advice for the maintenance EX 90 3G AI TR EX 90 3G AI AL TR EX 90 4G AI AL EX 90 5G AI AL TR EX 90 5G AI AL TR CI EX 90 5G AI AL PC CI Instructions Manual EX 90 3G AI TR EX 90 3G AI AL TR EX 90 4G AI...

Страница 2: ...ed steel pan support 2F left 11 Central enamelled steel pan support 12 Enamelled steel pan support fish central burner 13 Burner n 1 control knob 14 Burner n 2 control knob 15 Burner n 3 control knob...

Страница 3: ...correctly place In the event of the Burner flames being accidentally extinguished turn off the burner control and do not attempt to re ignite the burner for a least 1 minute HOW TO USE THE BURNERS Be...

Страница 4: ...The room must therefore be well ventilated by keeping the natural air vents clear fig 3 and by activating the mechanical aeration device suction hood or electric fan fig 4 and fig 5 Intensive and len...

Страница 5: ...bodies Check that enamelled burner cap C fig 6 have correctly positioned on the burner head It must be steady The exact position of the pan support is established by the rounded corners which should...

Страница 6: ...surements of the opening made in the top of the modular cabinet and into which the hot plate will be installed are indicated in either fig 7 Always comply with the measurements given for the hole into...

Страница 7: ...stick the plastic laminate to the cabinet must be able to withstand a temperature of not less than 150 C otherwise the laminate could come unstuck The appliance must be installed in compliance with th...

Страница 8: ...bottle In case of liquid bottledgas supply mount a pressure governor according to the regulations in force To connect the hob with the bottled pressure governor use a flexible tube 95 cm lenght fasten...

Страница 9: ...overtemperature of 65K Never use reductions adapters of shunts for connection since these could create false contacts and lead to dangerous overheating The outlet must be accessible after the built i...

Страница 10: ...he provisions established by the provisions governing such appliances 10 FIXING THE HOT PLATE The hot plate has a special seal which prevents liquid from infiltrating into the cabinet Strictly comply...

Страница 11: ...emove knob M fig 14 of the tap which is simply pressed on to its rod Insert a small screwdriver D into hole C fig 14 and turn the throttle screw to the right or left until the burner flame has been ad...

Страница 12: ...abels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate chart also lists the heat inputs of the burners the diameter of t...

Страница 13: ...G30 BUTANE 28 30 127 65 500 1750 35 G20 NATURAL 20 167 97 Z 500 1750 Adj BURNERS N DESCRIPTION GAS NORMAL PRESSURE NORMAL RATE INJECTOR DIAMETER NOMINAL HEAT INPUT W mbar g h l h 1 100 mm MIN MAX 1 1...

Страница 14: ...TOWN GUANGZHOU 20 383 140 1 800 2800 Adj BUTANE 30 127 65 500 1750 32 TOWN SHANGHAI 10 459 200 2 500 1750 Adj TOWN GUANGZHOU 20 223 110 1 500 1750 Adj BURNERS N DESCRIPTION GAS NORMAL PRESSURE NORMAL...

Страница 15: ...ced to ensure a perfect tightness Greasing the taps see fig 20 21 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean th...

Страница 16: ...l for our ambient Always put them in a separate and safe container If you eliminate your appliance remember to take off the battery CAUTION The device should not be operated for more than 15 second If...

Страница 17: ...cable is replaced the installer should leave the ground wire longer than the phase conductors fig 23 and comply with the recommendations given in paragraph 8 Gas hot plate H05 RR F Section 3 x 0 75 m...

Страница 18: ...H BATTERY 5 BURNERS CENTRALUR LPG 28 30 mbar LPG 37 mbar NATURAL 20 mbar Qn LPG Gas Rate 10 40 kW Qn LPG Gas Rate 756 g h Voltage 220 230 V Frequency 50 Hz 3 BURNERS CENTRALUR LPG 28 30 mbar LPG 37 mb...

Страница 19: ...V Frequency 50 Hz 5 BURNERS CENTRALFISH LPG 28 30 mbar NATURAL 20 mbar Qn LPG Gas Rate 10 10 kW Qn LPG Gas Rate 735 g h Voltage 220 230 V Frequency 50 Hz 5 BURNERS CENTRALUR LPG 28 30 mbar NATURAL 20...

Страница 20: ...WN SHANGHAI 10 mbar TOWN GUANGZHOU 20 mbar Qn Town Gas Rate 7 65 kW Qn LPG Gas Rate 8 1 kW Qn LPG Gas Rate 589 g h Voltage 1 5 V DC 5 BURNERS CENTRAL UR LPG 30 mbar TOWN SHANGHAI 10 mbar TOWN GUANGZHO...

Страница 21: ...our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare...

Страница 22: ...62 01 600 3 762 01 626 MALAYSIA Mexico Mexico D F TEKA MEXICANA S A DE C V 52 5 762 04 90 5 762 05 17 Poland Warszawa TEKA POLSKA SP Z O O 48 22 652 18 94 22 850 12 48 Portugal Ilhavo TEKA PORTUGUESA...

Страница 23: ...23...

Страница 24: ...24...

Отзывы: