11
Description
Parameter
Value
Unit
k-Value
k
0.23
Smart control compliance
smart
0
Smart control factor
SCF
0
Conversion coefficient
CC
2.5
Ambient correction term
Q
cor
-0.357
kWh
Referenct energy
Q
ref
5.845
kWh
Useful energy content
Q
H2O
6.234
kWh
Correction ratio of reference and useful energy
Q
ref/
Q
H2O
0.938
kWh
Daily electricity consumption (measured)
Q
test_elec
6.944
kWh
Water temperature at the beginning of the 24h measurement
cycle
T3
75.3
℃
Water temperature at the end of the 24h measurement cycle
T5
76.1
℃
Storage volume
M
act
50.8
kg
Storage volume
C
act
50.8
L
Daily electricity consumption (corrected)
Q
elec
6.466
kWh
Water heating energy efficiency
η
wh
37.0
that correspond to the water heating efficiency class
The product fulfills and corresponds to the requirements of the commission regulation
standards (No 814/2013) for electrical storage water heater and achieved a water
heating energy efficiency of
In accordance with Annex
Ⅱ
Enercy Efficiency Classes article 1 of the commission
regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related
commission regulation (No 812/2013 and 814/2019) is only a part of the conformity
assessment to achieve the ErP-Label.
Electricity consumption Q
elec
、
water heating energy efficiency
η
wh
and mixed water
at 40
℃(
V40
)
“C”
η
wh
=37%
Annual Electricity Consumption
AEC
1389
kWh
Water heating energy efficiency class
C
Description
Parameter
Value
Unit
Water temperature without tapping
T
set
76.5
℃
Average water temperature of outlet warm water
θ
'
p
69.5
℃
Average water temperature of inlet cold water
θ
c
10.2
℃
Normalised value of the average temperature
θ
p
69.4
℃
Volume that delivered water of at least 40
℃
V
40exp
40.4
L
Calculated volume that delivered hot water of at least 40
℃
V
40
80
L
he electrical storage water heater
EWH 50 VR1.5
of the company
TEKA
Industrial, S.A. was tested with a declared load profile of the size