Teka E/70 2G AI TR Скачать руководство пользователя страница 12

12

10) INSTALLING THE HOT PLATE
WITH THE BATTERY

Check that the appliance is in a good condition after
having removed the outer packaging and internal
wrappings from around the various loose parts. In
case of doubt, do not use the appliance and contact
qualified personnel.

Never leave the packaging materials (cardboard,
bags, polystyrene foam, nails, etc.) within
children’s reach since they could become
potential sources of danger.

The measurements of the opening made in the top
of the modular cabinet and into which the hot plate
will be installed are indicated in either fig. 9. Always
comply with the measurements given for the hole
into which the appliance will be recessed (see fig. 9
and 10).

The appliance belongs to class 3 and is therefore
subject to all the provisions established by the
provisions governing such appliances.

11) FIXING THE HOT PLATE

The hot plate has a special seal which prevents
liquid from infiltrating into the cabinet. Strictly
comply with the following instructions in order to
correctly apply this seal:
- Detach the seals from their backing, checking that

the transparent protection still adheres to the seal
itself.

- Overturn the hot plate and correctly position seal

“E” (fig. 11) under the edge of the hot plate itself,
so that the outer side of the seal perfectly matches
the outer perimetral edge of the hot plate. The
ends of the strips must fit together without
overlapping.

- Unscrew the ignition cap “T” (see fig. 14) and fit a

1,5 V battery (not included in the appliance) with
the positive “+” polarity turn inside. Rescrew the
cap.

- Evenly and securely fix the seal to the hot plate,

pressing it in place with the fingers.

- Fix the hob with the proper brackets “S” and fit the

prominent part into the porthole “H” on the
bottom; turn the screw “F” until the bracket “S”
stick on the top (fig. 12).

INSTALLATION

FIG. 14

Содержание E/70 2G AI TR

Страница 1: ...tallation and advice for the maintenance E 70 2G AI TR E 70 3G AI TR E 70 5G AI TR E 70 2G AI TR AL E 70 3G AI TR AL E 70 5G AI TR AL Instructions Manual E 70 2G AI TR E 70 3G AI TR E 70 5G AI TR E 70...

Страница 2: ...ntral enamelled steel pan support for ur 8 Central enamelled steel pan support 9 Burner n 1 control knob 10 Burner n 2 control knob 11 Burner n 3 control knob 12 Burner n 4 control knob 13 Electric ig...

Страница 3: ...ap is not correctly place In the event of the Burner flames being accidentally extinguished turn off the burner control and do not attempt to re ignite the burner for a least 1 minute HOW TO USE THE B...

Страница 4: ...ents clear fig 3 and by activating the mechanical aeration device suction hood or electric fan fig 4 and fig 5 Intensive and lengthy use of the appliance may require additional ventilation This can be...

Страница 5: ...the plate is operating A purely indicative regulation table for the normal electric plates is given below NORMAL AND RAPID PLATES HEAT INTENSITY POSSIBLE COOKING PROCESSES TABLE 0 1 2 3 4 5 6 Off Wea...

Страница 6: ...he plates are being used Make sure that there are no children in the near vicinity Particularly make sure that the pan handles are correctly positioned and keep a check on foods requiring oil and gras...

Страница 7: ...burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they are d...

Страница 8: ...ndicated in either fig 9 Always comply with the measurements given for the hole into which the appliance will be recessed see fig 9 and 10 The appliance belongs to class 3 and is therefore subject to...

Страница 9: ...able to withstand a temperature of not less than 150 C otherwise the laminate could come unstuck The appliance must be installed in compliance with the provisions in force This appliance is not connec...

Страница 10: ...e by means of the safety clamp specified by standards In case of liquid bottledgas supply mount a pressure governor according to the regulations in force To connect the hob with the bottled pressure g...

Страница 11: ...ust be positioned so that no part of it is able to reach an overtemperature of 75 K Never use reductions adapters of shunts for connection since these could create false contacts and lead to dangerous...

Страница 12: ...ing such appliances 11 FIXING THE HOT PLATE The hot plate has a special seal which prevents liquid from infiltrating into the cabinet Strictly comply with the following instructions in order to correc...

Страница 13: ...which is simply pressed on to its rod Insert a small screwdriver D into hole C fig 15 and turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Redu...

Страница 14: ...thorized customer Service Centre For the sake of convenience the nominal rate table also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various typ...

Страница 15: ...00 62 NATURAL 20 352 130 T 1400 3700 62 TOWN SHANGHAI 10 971 330 3 1400 3700 62 TOWN GUANGZHOU 20 472 165 2 1400 3700 62 LPG 30 218 70 750 3000 45 NATURAL 20 286 91 Z 750 3000 45 TOWN SHANGHAI 10 787...

Страница 16: ...000 45 TOWN 10 581 270 3 750 3000 45 LPG 30 127 65 500 1750 35 TOWN 10 339 190 2 500 1750 35 BURNERS N DESCRIPTION GAS NORMAL PRESSURE NORMAL RATE INJECTOR DIAMETER NOMINAL HEAT INPUT W mbar g h l h 1...

Страница 17: ...a tap is replaced to ensure a perfect tightness Greasing the taps see fig 21 22 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions Remove th...

Страница 18: ...ur ambient Always put them in a separate and safe container If you eliminate your appliance remember to take off the battery FIG 23 CAUTION The device should not be operated for more than 15 second If...

Страница 19: ...PE OF SINGLE PHASE HOT PLATE CABLE POWER SUPPLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installe should leave the ground wire longer than the phase conductors fig...

Страница 20: ...30 mbar PROPANE 37 mbar NATURAL 20 mbar Tot Nom Gas Rate 7 4 kW Tot Nom LPG Rate 538 g h Voltage 220 230 V Frequency 50 Hz OTHER MARKETS 5 BURNERS BUTANE 28 30 mbar PROPANE 37 mbar NATURAL 20 mbar Tot...

Страница 21: ...LPG 30 mbar TOWN 10 mbar Tot Nom LPG Gas Rate 7 4 kW Tot Nom H K TowngasRate 8kW Tot Nom LPG Rate 538 g h Voltage 220 230 V Frequency 50 Hz 5 BURNERS LPG 30 mbar TOWN 10 mbar Tot Nom LPGGasRate 11 2k...

Страница 22: ...L 20 mbar TOWN SHANGHAI 10 mbar TOWN GUANGZHOU 20mbar Tot Nom Gas Rate 7 4 kW Tot Nom LPG Rate 538 g h Voltage 220 230 V Frequency 50 Hz 5 BURNERS LPG 30 mbar NATURAL 20 mbar TOWN SHANGHAI 10 mbar TOW...

Страница 23: ...ency 60 Hz 2 UR BURNERS LPG 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 7 4 kW Tot Nom LPG Rate 538 g h Voltage 110 V Frequency 60 Hz 5 BURNERS LPG 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 11 2 kW Tot No...

Страница 24: ...RNERS LPG 30 mbar TOWN 10 mbar Tot Nom LPGGasRate 6 7kW Tot Nom TowngasRate 6 2kW Tot Nom LPG Rate 488 g h Voltage 220 230 V Frequency 50 Hz 5 BURNERS LPG 30 mbar TOWN 10 mbar Tot Nom LPGGasRate 10 85...

Страница 25: ...50 60 Hz 2 UR BURNERS LPG 28 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 7 4 kW Tot Nom LPG Rate 538 g h Voltage 220 V Frequency 50 60 Hz 5 BURNERS LPG 28 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 11 2 k...

Страница 26: ...Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only ava...

Страница 27: ...01 600 3 762 01 626 MALAYSIA Mexico Mexico D F TEKA MEXICANA S A DE C V 52 5 762 04 90 5 762 05 17 Poland Warszawa TEKA POLSKA SP Z O O 48 22 652 18 94 22 850 12 48 Portugal Ilhavo TEKA PORTUGUESA LT...

Страница 28: ...28...

Отзывы: