14
Important!
The transformation of the appliance to use a
d i ff e rent gas to that for which it has been
sold must only be carried out by a qualified
technician.
I n f o rmation for the Technical Serv i c e :
in the
event of conversion of the type of gas or
p re s s u re in the appliance, the new re g u l a t i o n
label must be placed over the existing one, in
o rder to identify the new characteristics after
the changeover.
To make the transformation replace the gas
nozzles and regulate the minimum settings of
the taps.
The gas nozzles necessar y for each type of
gas are indicated in table 1.
To replace the gas nozzles
it is necessary to
follow the following instructions:
• Remove the pan suppor ts and the top part
of the burners in order to access the nozzle.
• Use a no 7 tubular spanner to remove
th e no zzl es an d re pl ac e th em wi th th e
c o rresponding alternative nozzles. Take care
to tighten the nozzles well so as to avoid the
risk of gas leaks.
• Reposition the pan suppor t and burn e r
covers.
Once the gas nozzles have been replaced, the
following instructions must be followed
to
graduate the minimum settings
.
Hob CG.1 4G, CG.1 3G 1P, CGC 4G y CGC 4G
AI AL
•
Remove the oven or the control panel fro m
their place to access the gas taps.
•
Light the burners at their minimum setting.
•
Use a small screw driver to remove the
s c rew on the right or centre of the plug of
the gas key (turn left for a big flame and
right for a small flame).
•
Once the setting has been graduated
check that the flame remains at its mini-
mum setting when the control is bru s q u e l y
t u rned between the maximum and the
minimum setting.
•
In order to access the screw which gradua-
tes the gas flow through the taps in hob
CGC 4G AI AL, remove the screws that fix
the cover protecting the taps to the case
and lift the cover.
Gas trasformation
Table 1
CG LUX-60, CG LUX-70, CGC 4G, CG.1 4G, CG.1 3G. 1P.
CG Lux-75 and CG Lux-86
Burner
Family
First
Second
Third
Group a
Group c
Group e
Group H
Group E+
Group 3+
Triple ring
290
290
290
135
135
95
Fast
260
260
260
116
116
85
Semi fast
185
185
185
97
97
65
Auxiliar y
145
145
145
72
72
50
Gas nozzle diameter (Ø) expressed in 1/100 mm
61401134/329 ingles 18/7/03 16:55 Página 14