Model
F42‐217P4BL‐0104QM4‐JR
Frequency Range
60‐120 Hz
Total Head
Per multi‐speed curve
ft
Voltage
380 V
Capacity
Per multi‐speed curve
gpm
Phase
3
Min. Flow
5.28
gpm
Pole
2
Fluid
Input Range
1.6 - 10.8 kW
Temp.
‐50
°
F
Current Range
6.8 - 21.0 A
S.G.
0.70
Vis.
0.31 cp
Estimated Performance Curve (‐50°F
)
Aqueous NH3
REV.
Date
Description
APPROVED BY
CHEKED BY
DRAWN BY
TEIKOKU USA INC
120 Hz
100 Hz
80 Hz
60 Hz
0
2
4
6
8
10
12
Inpu
t Power
[kW
]
120 Hz
100 Hz
80 Hz
60 Hz
0
1
2
3
4
5
0
5
10
15
20
25
30
35
40
NPSHr
[ft]
Flow Rate [GPM]
300
250
200
150
100
50
120 Hz
100 Hz
80 Hz
60 Hz
0
200
400
600
800
1000
1200
TDH
[ft]
120 Hz
100
Hz
80 Hz
60 Hz
0
5
10
15
20
25
30
Ov
er
all
Efficiency
(%)
Min.
Flow
NH3 ∆P
(PSI)
Appx. H. NH
3
Reference Curve (-50°F)