F- THINGS THAT MUST BE DONE BEFORE CALLING AUTHORIZED
SERVICE
26
MESSAGE
REASON
PROCEEDINGS TO BE FOLLOWED
P1
Room sensor failure
Check the sensor connection
P2 sen
Evaporator sensor failure
Check the sensor connection before replacing the sensor.
HA pa-
Maximum temperature alarm
Check compressor operation and relevant parameter values.
LA pa-
Maximum temperature alarm
Check compressor operation and relevant parameter values.
EA
External alarm
Alarm stops automatically when digital entry is deactivated.
MESSAGE
REASON
PROCEEDINGS TO BE FOLLOWED
EO
Control sensor 1 failure
(Control)
Check the sensor
E1
Control sensor 2 failure
(Defrost)
Check the sensor and d0=0/1/4,F0=1
E2
Control sensor 3 failure
(Condenser)
Check the sensor and whether it is (A4=10)
IA
External alarm
Check external alarm outlets or A4 and A7 parameters.
dOr
Open door alarm
Check that the door is closed or A4 and A7 parameters.
LO
Low temperature alarm
returns to the set value range. Also check the set value.
HI
High temperature alarm
returns to the set value range. Also check the set value. Check
whether the cooling system runs properly.
EE/Eer
Unit parameter failure
Check the parameters.
EF
Operating parameter failure
ED
Defrost completed out of
its time
dT, dP ve d4 parametrelerini; defrost etkisini kontrol et. Defrost
i
�
lemi normal olarak
bittiğinde
alarm
kapanacaktır.
Содержание UFFS 45
Страница 1: ...TEFCOLD COMMERCIAL TYPE VERTICAL FROZENFOOD STORAGE CABINET OPERATING MANUAL...
Страница 2: ......
Страница 4: ......
Страница 7: ...4 WARNING CAUTION NOTE SUGGESTION NOTE Dear Customer and SUGGESTION read each of them carefully...
Страница 11: ...8 NOTE another purpose product A THINGS THAT MUST BE DONE BEFORE USING YOUR PRODUCT ANDSECURITYWARNINGS...
Страница 19: ...D USINGYOUR PRODUCT 16 WARNING PICTURE 11 PICTURE 12 PICTURE 13 Start up...
Страница 24: ...D USINGYOUR PRODUCT 21 Your product has manual defrost...
Страница 31: ......
Страница 32: ......