background image

31

GB

There is no steam or there is
little steam.

The water tank is
empty (red light on).

Fill the water tank. 

The steam output control dial is
set at minimum.

Increase the steam output (control dial on the
control panel).

The soleplate temperature is set to
the maximum.

The generator is working but steam is very hot and
dry. As a consequence, it is less visible.

The red “water
tank empty” light is on.

The water tank is empty.

Fill the water tank.

Steam escapes from anti-
scale valve plug.

The anti-scale valve plug has not been
tightened correctly.

Tighten the anti-scale valve plug correctly.

The anti-scale valve is damaged

Contact an Approved Service Centre to order a new anti-
scale valve.

Steam or water escapes
under the appliance.

The generator is faulty.

Stop using the generator and contact an Approved
Service Centre.

Environment protection first !

Your appliance contains valuable materials which can be recovered or recycled.

Leave it at a civic waste disposal centre.

If you have any problems or queries please call our Customer Relations team first for expert help and

advice: 0845 602 1454 - UK

(01) 677 4003 - Ireland

or consult our website - www.tefal.co.uk

Notice Protect  17L 1800111440  13/02/08  14:47  Page 31

Содержание Protect Anti-Calc GV9360

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ...r appliance before rinsing the anti scale valve or filling the water tank before cleaning your generator after each use The appliance must be used and placed on a flat stable heat resistant surface Wh...

Страница 5: ...g brown staining or premature wear of the appliance water from clothes dryers scented or softened water water from refrigerators batteries or air conditioners pure distilled or demineralised water or...

Страница 6: ...control dial located on the control panel While ironing the light on top of the iron and the steam ready light turn on and off as the temperature adjusts without interrupting ironing To obtain steam...

Страница 7: ...l position tilted slightly forwards press repeatedly on the steam control button underneath the iron handle moving the iron from top to bottom fig 9 Refilling the water tank When the red tank empty in...

Страница 8: ...wa at te er r m ma ay y f fllo ow w o ou ut t o of f t th he e t ta an nk k w wh he en n i it t i is s o op pe en ne ed d Once the generator has cooled down completely remove the anti scale valve cap...

Страница 9: ...he soleplate is not hot enough Decrease the steam output while ironing at low temperature steam output control dial on the control panel Wait for the thermostat light to go out before activating the s...

Страница 10: ...ug The anti scale valve plug has not been tightened correctly Tighten the anti scale valve plug correctly The anti scale valve is damaged Contact an Approved Service Centre to order a new anti scale v...

Отзывы: