background image

29

GB

Maintenance and cleaning

Cleaning your generator

• Do not use detergent or descaling products for cleaning the soleplate

base-unit.

• Never hold the iron or the base unit under the tap.
• Regularly clean the soleplate with a damp, n

no

on

n--m

me

etta

alllliicc  w

wa

assh

hiin

ng

g  u

up

p  p

pa

ad

d..

• Clean the plastic parts of the appliance occasionally with a soft cloth.

Cleaning tip: For
easier, non-corrosive
cleaning of your iron’s
soleplate, use a damp
sponge on the
soleplate while it is
still warm.

Descaling your generator easily:   

For longer generator life, and to avoid scale emissions, your generator
is equipped with a built-in anti-scale valve. This valve, located in the tank, auto-
matically removes the scale that forms inside. 

O

Op

pe

erra

attiio

on

n::

• An orange “anti-scale” light located on the control panel starts blinking to tell you

that the anti-scale valve needs rinsing - 

fig.13

C

Ca

au

uttiio

on

n::  tth

hiiss  o

op

pe

erra

attiio

on

n  m

mu

usstt  n

no

ott  b

be

e  p

pe

errffo

orrm

me

ed

d  u

un

nttiill  tth

he

e  g

ge

en

ne

erra

atto

orr  h

ha

ass  b

be

ee

en

n

u

un

np

pllu

ug

gg

ge

ed

d  ffo

orr  a

att  lle

ea

asstt  ttw

wo

o  h

ho

ou

urrss  a

an

nd

d  h

ha

ass  cco

om

mp

plle

ette

elly

y  cco

oo

olle

ed

d  d

do

ow

wn

n..

W

Wh

he

en

n  p

pe

errffo

orrm

miin

ng

g  tth

hiiss  o

op

pe

erra

attiio

on

n,,  tth

he

e  g

ge

en

ne

erra

atto

orr  ssh

ho

ou

ulld

d  b

be

e  p

plla

acce

ed

d  n

ne

ea

arr  a

a  ssiin

nkk  a

ass

w

wa

atte

err  m

ma

ay

y  ffllo

ow

w  o

ou

utt  o

off  tth

he

e  tta

an

nkk  w

wh

he

en

n  iitt  iiss  o

op

pe

en

ne

ed

d..

• Once the generator has cooled down completely, remove the anti-scale

valve cap - 

fig.16

• Unscrew the anti-scale valve and remove it from the housing; it contains the scale

that has built up in the tank - 

fig.17 and fig.18

.

• To clean the valve properly, just rinse it under running water to remove

the scale it contains - 

fig.19

.

• Put the valve back into its housing and screw it in completely to keep

it watertight - 

fig.20

.

• Put the cap back on.

T

Th

he

e  n

ne

exxtt  ttiim

me

e  y

yo

ou

u  u

usse

e  y

yo

ou

urr  iirro

on

n,,  p

prre

essss  tth

he

e  ““rre

esse

ett””  b

bu

utttto

on

n  o

on

n  tth

he

e  cco

on

nttrro

oll  p

pa

an

ne

ell  tto

o

ttu

urrn

n  o

offff  tth

he

e  o

orra

an

ng

ge

e  ““a

an

nttii--sscca

alle

e””  lliig

gh

htt..

Do not use any descaling
substances (vinegar,
industrial descaling
products, etc.) when
rinsing anti-scale valve :
they could damage it.
Before descaling and
cleaning your generator,
you must let it cool down
for at least 2 hours to
avoid any risk of burns.

“Auto off” System

• For your safety, the generator is equipped with an “auto off” system which

switches the generator to standby mode if it is not used for 8 minutes or if you
forget to turn it off.

• A red light blinks on the control panel to indicate that the appliance is in

standby mode - 

fig.15

.

• To reactivate the generator:

- Press the “Restart” button.
- Wait for the light on the “steam ready” button to stop blinking before your start
ironing again.

• If the steam trigger is not pressed for at least 8 minutes, the “auto off” system

will cut off your generator for your safety.

Notice Protect  17L 1800111440  13/02/08  14:47  Page 29

Содержание Protect Anti-Calc GV9360

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ...r appliance before rinsing the anti scale valve or filling the water tank before cleaning your generator after each use The appliance must be used and placed on a flat stable heat resistant surface Wh...

Страница 5: ...g brown staining or premature wear of the appliance water from clothes dryers scented or softened water water from refrigerators batteries or air conditioners pure distilled or demineralised water or...

Страница 6: ...control dial located on the control panel While ironing the light on top of the iron and the steam ready light turn on and off as the temperature adjusts without interrupting ironing To obtain steam...

Страница 7: ...l position tilted slightly forwards press repeatedly on the steam control button underneath the iron handle moving the iron from top to bottom fig 9 Refilling the water tank When the red tank empty in...

Страница 8: ...wa at te er r m ma ay y f fllo ow w o ou ut t o of f t th he e t ta an nk k w wh he en n i it t i is s o op pe en ne ed d Once the generator has cooled down completely remove the anti scale valve cap...

Страница 9: ...he soleplate is not hot enough Decrease the steam output while ironing at low temperature steam output control dial on the control panel Wait for the thermostat light to go out before activating the s...

Страница 10: ...ug The anti scale valve plug has not been tightened correctly Tighten the anti scale valve plug correctly The anti scale valve is damaged Contact an Approved Service Centre to order a new anti scale v...

Отзывы: