PRIOR TO USE

Review all product support materials with the Teeter Hang Ups Gravity Boots

 

and Inversion Table before inverting with the Teeter Hang Ups Conversion Bar.

1. Preparing the Inversion Table

•  Confirm that the Main Shaft is adjusted to your proper height setting.
•  Adjust the Ankle Comfort Dial (up or down) to ensure the hooks are securly

 

hooked to the Conversion Bar with the bar touching or nearly touching the base

 

of the hook while the feet rest flat on the Ankle Comfort Dial.

2. Mounting 

•  While facing away from the table with your legs positioned on either side of the 

Main Shaft, lift one foot so that Gravity Boot Hook on the boot wraps around

 

the Conversion Bar. 

•  Slide the hook along the Conversion Bar until the foot is able to rest flat on

 

the Ankle Comfort Dial (Figure 4).

Figure 4

WARNING

!

Setting the Ankle Comfort Dial so that the hooks are not securely around the bar 

could cause you to fall during inversion, resulting in serious injury or death! 

International: 

Inversion International, Ltd. 

(Phone) +1-242-362-1001 · (Fax) +1-242-362-1002  

[email protected] · www.InversionInternational.com

If you have any problems assembling the equipment or questions about its use, please contact customer service at: 

USA: 

Teeter 

Toll Free (Phone) 800-847-0143 · (Fax) 800-847-0188

[email protected] · www.teeter-inversion.com

DO NOT DISCARD - KEEP FOR FUTURE REFERENCE

Teeter Hang Ups® is a registered trademark of Teeter © COPYRIGHT 2011, Teeter.. LB-1003 0511-4

To re-assemble the Ankle Clamps - 

reverse the process

•  Remove the black end cap from the back of the ankle clamp housing (Figure 5).

•  Follow Step Three through Step One, reversing the installation process to remove the 

Conversion Bar and re-assemble the rear and front ankle clamp assemblies (Figures 6 & 7).

•  IMPORTANT FOR FRONT ANKLE CLAMP ASSEMBLY:

  - Make sure that the holes in the front ankle clamp assembly

 

  are on top (facing the same side as the locking pin). 

  - When inserting the bolt into the holes in the housing, be sure to slide

 

  the bolt through the loops at the end of the spring and security cable. 

  You may need to use needle nose pliers to pull and align the spring

 

  loop and cable with the bolt.

  - Fasten securely with the nut. Test the installation of the front ankle

 

  clamps to ensure there is spring-loaded tension. 

  - Replace the black end cap on the back of the ankle clamp housing.

•  If you removed the locking pin when you installed the Conversion Bar, you MUST replace

 

it securely before using the ankle clamp assembly. Use channel locks or vise grips to ensure 

that the locking pin is fully tightened. You may want to wrap the base of the locking pin

 

with a cloth to prevent cosmetic scarring when tightening. 

RE-ASSEMBLING THE ANKLE CLAMPS

WARNING

!

Failure to properly re-assemble the ankle clamps, including the T-Pin,

 

could cause serious injury or death! Test the locking function of the

 

ankle clamp assembly prior to use.