Models 4RK45A, 4RK46A, 4RK47A, 
4RK48A, 4RK49A, 4RK62A and 4RK63A

7

Teel Operating Instructions and Parts Manual

E

N
G

L

I

S

H

®

Troubleshooting

Read and understand safety and
operating instructions in this manual
before doing any work on pump!

Only qualified personnel should
electrically test pump motor.

Risk of electrical

shock. Disconnect

power to outlet before handling pump or
motor.

Risk of electrical
shock. Disconnect

power to outlet before handling pump or
motor. Sudden Starts. If power to pump is
ON when thermal overload resets, pump
may start without warning. If you are
working on pump, you may get an
electrical shock or impeller may catch
fingers or tools.

Symptom

Possible Cause(s)

Corrective Action

Pump fails  

1. Power to pump has been interrupted

1. Check to be sure you have power to your home. 

to operate

Check to be sure that power cord is securely 
plugged into outlet or securely wired into 
controller or switch box 

2. Liquid fluid level is not high enough  

2. Check that fluid level is high enough to activate  

to activate switch or controller

switch or controller

3. Plugged vent hole in discharge pipe

3. Check to be sure that the 3/16” vent hole in 

discharge pipe is not plugged

4. Pump inlet, impeller, check valve or  

4. Check for blockage in pump inlet, impeller, check 

discharge pipe are blocked

valve, or discharge pipe

5. Thermal overload may have tripped

5. Test start pump; if it starts and then stops 

immediately, disconnect from power source for 
30 minutes to allow motor to cool, then reconnect 
to power source. Check for cause of overheating

Pump fails to   

1. All valves in discharge pipe are not  

1. Check to be sure all valves in discharge pipe are  

empty sump

fully open

fully open

2. Discharge pipe and check valve 

2. Clean out discharge pipe and check valve

are clogged

3. Pump inlet or impeller have blockage

3. Remove blockage in pump inlet or impeller

4. Pump not sized correctly

4. A higher capacity pump may be needed

Pump will not     

Switch or automatic float control   

See installation instructions for switch/controller   

shut off 

are functioning improperly

Troubleshooting Chart

Содержание 4RK45A

Страница 1: ...ameter Length Weight 4RK45A 1 230 1 8 5 15 130 F Sewage solids handling 3 4RK46A 1 230 460 3 8 5 4 1 15 15 130 Sewage solids handling 3 4RK47A 11 2 230 1 12 0 15 130 Sewage solids handling 3 4RK48A 11...

Страница 2: ...to install pump with a magnetic motor starter wired to interrupt power to all three incoming phases Three phase pumps are intended for permanent connection only Provide strain relief at control box fo...

Страница 3: ...fications on Page 1 OVERLOADS SINGLE PHASE In single phase units an automatic overload protector in the motor will protect motor from burning out due to overheating overloading When motor cools down p...

Страница 4: ...d will void warranty 4 Use lifting ring on top of pump for all lifting lowering of pump Disconnect power to pump before doing any work on pump or attempting to remove pump from sump IMPELLER SEAL AND...

Страница 5: ...motor cover from seal plate Ref No 10 Remove through bolts Ref No 15 from motor assembly Ref No 8 Remove motor and shaft from seal plate 10 Working from back of seal plate tap primary seal head out of...

Страница 6: ...ress or imply a warranty that the products are MERCHANTABLE or FIT FOR A PARTICULAR PURPOSE or that the products will necessarily conform to the illustrations or descriptions Except as provided below...

Страница 7: ...el is not high enough 2 Check that fluid level is high enough to activate to activate switch or controller switch or controller 3 Plugged vent hole in discharge pipe 3 Check to be sure that the 3 16 v...

Страница 8: ...62SS U30 62SS U30 62SS U30 62SS 4 14 1 4 20 x 1 Capscrew U30 475SS U30 475SS U30 475SS U30 475SS U30 475SS 4 15 Motor through bolts U30 941 U30 941 U30 941 U30 941 U30 941 4 16 3 16 x 3 4 Impeller ke...

Страница 9: ...U30 475SS U30 475SS 4 15 Motor through bolts U30 941 U30 941 4 16 Shaft seal U9 394SS U9 394SS 1 17 Retaining washer PW43 5SS PW43 5SS 1 18 Retaining ring U9 353SS U9 353SS 1 19 Lip seal U9 417 U9 417...

Страница 10: ...Notes Teel Operating Instructions and Parts Manual 4RK45A 4RK46A 4RK47A 4RK48A 4RK49A 4RK62A and 4RK63A E N G L I S H Manufactured for Dayton Electric Mfg Co Niles Illinois 60714 U S A...

Отзывы: