Teel Engine Driven High
Pressure Centrifugal Pump
Operating Instructions & Parts Manual
4RJ45
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Form 5S4180
®
E
N
G
L
I
S
H
Printed in U.S.A.
09319
0798/139/E3
Unpacking and Inspection
Handle with care. Check items received
against packing list to be sure that all
equipment has been received. Inspect
for shipping damage. If found, file
claim with carrier immediately.
General Safety Information
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol.
When you see this symbol on your
pump or in this manual, look for one of
the following signal words and be alert
to the potential for personal injury.
Warns about
hazards
that will cause serious personal injury,
death or major property damage if
ignored.
Warns about
hazards that can
cause serious personal injury, death or
major property damage if ignored.
Warns about
hazards that will
or can cause minor personal injury or
property damage if ignored.
NOTE:
Indicates special instructions
which are important but not related to
hazards.
Carefully read and follow all safety
instructions in this manual and on
pump.
Keep safety labels in good condition.
Replace missing or damaged safety
labels.
Electrical Safety
Do not allow pump or any system com-
ponent to freeze. To do so will void
warranty.
Pump water only with this pump.
Periodically inspect pump and system
components.
Wear safety glasses at all times when
working on pumps.
Keep work area clean, uncluttered,
and properly lighted; store properly all
unused tools and equipment.
Keep visitors at a safe distance from
the work areas.
Pump body may
explode if used as
a booster pump unless relief valve
capable of passing full pump flow at 75
psi is installed.
IMPORTANT:
For best possible
performance and continuous,
satisfactory operation, read these
instructions before installing your new
pump. Should service be required, this
manual can be a valuable guide, it
should be kept near the installation for
ready reference.
Rotating parts. Can
catch hands, feet,
or clothing. Stay clear of equipment
and keep shields in place while pump is
running. Stop motor or engine before
servicing pump. Read owner’s manual
before using equipment.
5
Tecumseh
3
1, 1
1
/
2
, 2
1
1
⁄
2
”
17”
15
1
⁄
2
”
18
1
⁄
2
”
75 lbs.
Specifications
Engine
Fuel Tank
Oulet Port
Inlet Port
Dimensions
HP
Type
Size (Qts.)
Size (NPT)
Size (NPT)
H
W
L
Wt
Performance Chart
0
85
82
70
57
38
76
5
85
79
68
54
31
74
10
85
77
65
50
24
72
15
85
75
62
44
18
70
20
82
73
60
40
10
68
Suction
5 HP Pump
Maximum
Lift
Gallons Per Minute at Static Suction Lift (Feet)
Pressure
(In feet)
25’
35’
45’
55’
65’
(PSI)
Description
Teel portable, engine driven, self-priming pump Model Number 4RJ45, is used for
high pressure wash-downs, firefighting, pressure boosting, water transfer and
irrigation. Pump body is heavy duty aluminum. 5 HP Tecumseh engine provides
high suction lift, pressures to 76 psi, a capacity of 85 GPM, and multiple discharges
for running several lines at one time.