teel 4P035A Скачать руководство пользователя страница 2

General Safety Information

READ AND FOLLOW 
SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see this symbol on your

pump or in this manual, look for one of
the following signal words and be alert to
the potential for personal injury:

Warns about

hazards  

that will cause serious personal injury,
death, or major property damage if
ignored.

Warns about
hazards that can

cause serious personal injury, death, or
major property damage if ignored.

Warns about
hazards that will or

can cause minor personal injury or
property damage if ignored.

NOTE:

Indicates special instructions

which are important but not related to
hazards.

Carefully read and follow all safety
instructions in this manual and on
pump.

Keep safety labels in good condition. 
Replace missing or damaged safety
labels.

Electrical Safety

Capacitor voltage
may be hazardous.

To discharge motor capacitor, hold
insulated handle screwdriver BY THE
HANDLE and short capacitor terminals
together. Do not touch metal screwdriver
blade or capacitor terminals. If in doubt,
consult a qualified electrician. 

Wire motor for correct voltage. See

“Electrical” section of this manual

and motor nameplate.

Ground motor before connecting to

power supply.

Meet United States National Electri-

cal Code, Canadian Electrical Code,

and local codes for all wiring.

Follow wiring instructions in this

manual when connecting motor to

power lines.

Do not touch an
operating motor.

Modern motors are designed to operate
at high temperatures. To avoid burns
when servicing pump, allow it to cool for
20 minutes after shut-down before
handling.

Do not allow pump or any system com-
ponent to freeze. To do so will void
warranty.

Pump water only with this pump.

Periodically inspect pump and system
components.

Wear safety glasses at all times when
working on pumps.

Keep work area clean, uncluttered, and
properly lighted; store properly all
unused tools and equipment.

Keep visitors at a safe distance from the
work areas.

Pump body may
explode if used as a

booster pump unless relief valve capable
of passing full pump flow at 75 psi is
installed.

2

Teel Operating Instructions and Parts Manual

4RJ47, 4RJ48, 4RJ49, 4RJ50, 4P035A and 4P036A 

Teel Heavy Duty Cast Iron
Convertible Jet Pumps

®

E

N
G

L

I

S

H

Hazardous pressure! 
Install pressure relief 
valve in discharge pipe.

Release all pressure on 
system before working on 
any component.

WARNING

Hazardous voltage. 
Can shock, burn, or
cause death.

Ground pump before 
connecting to power 
supply. Disconnect power
before working on pump,
motor, or tank.

WARNING

Содержание 4P035A

Страница 1: ...fusers are highly stable high heat thermoplastic Teel convertible jet pump system Model 4RJ49 is a heavy duty convertible jet pump mounted on a 30 gallon horizontal tank Use it on shallow wells up to...

Страница 2: ...motor before connecting to power supply Meet United States National Electri cal Code Canadian Electrical Code and local codes for all wiring Follow wiring instructions in this manual when connecting...

Страница 3: ...20 30 40 50 20 30 40 50 GPH w J32P 24 Venturi 54 Nozzle GPH w J32P 32 Venturi 55 Nozzle GPH w J32P 24 Venturi 54 Nozzle 30 580 420 260 125 900 660 400 140 1070 865 635 385 40 485 325 180 48 720 520 26...

Страница 4: ...0 525 420 320 230 640 565 450 310 80 465 370 285 200 550 470 355 215 GPH w J32P 22 Venturi 53 Nozzle GPH w J32P 22 Venturi 54 Nozzle 90 320 250 190 135 400 345 290 230 100 280 225 170 120 350 300 250...

Страница 5: ...40 385 195 370 325 275 235 60 511 486 378 240 585 420 240 66 340 295 250 210 70 438 408 306 186 305 260 220 180 80 354 330 234 132 275 235 195 155 90 240 200 165 125 100 215 180 145 105 110 165 135 10...

Страница 6: ...n the venturi with the top hole on the front of the pump See Figure 5 NOTE Always replace the ejector when replacing the pump in a shallow well installation 3 Install the pump in the system Make sure...

Страница 7: ...LLATION 2 OR LARGER CASING FIGURE 7 1 Install ejector package 2P429A ejector is included on Model 4RJ49 pump tank system For other heavy duty jet pumps kits are sold separately Follow the instructions...

Страница 8: ...lon tape or a teflon based pipe joint compound on threaded pipe joints Protect the foot valve assembly from fish trash etc by installing a screen around it See Figure 9 4 Lower the pipe into the water...

Страница 9: ...e from the well to the pump Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so that it slopes slightly upward from the well to the pump high spots...

Страница 10: ...n tubing from the pump s AVC port to the port on the AVC mounted on the tank See instructions provided with tank and AVC for details You have just completed the tank connection for your jet pump Pleas...

Страница 11: ...B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connector Type Move black wire from A to L1 1 1 2 2 3 3 230 Volt to 115 Volt Conversion Plug in Type Pull plug straight out from termi...

Страница 12: ...d lead in a service panel to a metal underground water pipe to a metal well casing at least ten feet 3M long or to a ground electrode provided by the power company or the hydro authority 4 Connect the...

Страница 13: ...rder to get all the trapped air out of the piping Don t forget to close the control valve each time before you start the pump 5 When pressure has built up and stabilized at about 50 psi slowly open th...

Страница 14: ...ressure in the system and shut off check the pressure switch operation by opening a faucet or two and running enough water out to bleed off pressure until the pump starts The pump should start when pr...

Страница 15: ...er from seal plate See Figure 24 Exposed impeller can now be cleaned 2 If impeller must be replaced loosen two machine screws and remove motor canopy If motor has a capacitor go to step 3 If motor doe...

Страница 16: ...piping 11 Prime pump as described under Operation REMOVING OLD SEAL 1 Follow instructions under Pump Disassembly 2 Follow steps 1 through 5 under Cleaning Replacing Impeller 3 Remove rotating half of...

Страница 17: ...Operation 4 Check for leaks HELPFUL HINTS HOW TO AVOID OVERPUMPING A SHALLOW WELL In the section on Priming the Shallow Well Pump the instructions were to open the control valve all the way after the...

Страница 18: ...ve assembly L262 4PS L262 4PS L262 5PS L262 5PS L262 5PS 1 12 Pump body L76 48A L76 48A L76 49A L176 40 L176 40 1 13 1 4 NPT Drain plug 1 14 1 8 NPT Pipe plug 1 15 1 4 NPT Barbed fitting st 1 16 Switc...

Страница 19: ...r bushing 1 7 1 NPT Pipe plug 1 8 1 8 NPT Bayonet fitting 1 9 AVC Tube U37 626P 1 10 Air volume control U238 4 1 11 1 4 NPT Bayonet elbow 1 12 1 4 NPT x 11 2 Nipple 1 13 3 8 16 x 11 4 lg Carriage bolt...

Страница 20: ...s on nozzle instead of part number 1 Check valve assembly N212 12P 1 2 1 8 NPT sq hd teflon taped pipe plug 2 3 Ejector body N40 92 1 4 Nozzle 1 each 55 J34P 45 1 51 J34P 41 1 5 Gasket N20 25 1 6 Vent...

Страница 21: ...ler is plugged 3 Clean ejector or impeller see Maintenance 4 Check or foot valves stuck in closed 4 Replace check valve or foot valve position 5 Frozen pipe 5 Thaw pipes Bury pipes below frost line He...

Страница 22: ...m Certain aspects of disclaimers are not applicable to consumer products e g a some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitatio...

Отзывы: