teel 4P035A Скачать руководство пользователя страница 15

Maintenance (Continued)

2. Disconnect air volume control (AVC)

tubing and turn AVC 180°
counterclockwise. Any water in AVC
will then drain back into tank (See
Figure 21).

CLEANING DEEP WELL EJECTOR

1. Disconnect power.

2. Disconnect piping and well seal or

well casing adapter. (If pitless
adapter is used, piping does not
have to be disconnected).

3. Withdraw ejector assembly from

well.

4. Unscrew and remove pipe adapter

(if used).

5. Unscrew and remove the venturi.

Remove nozzle with a socket
wrench, if possible.

6. Clean nozzle as explained under

Step 8, “Cleaning Shallow Well
Ejector”, Page 16).

7. Reverse steps 1 through 5 to

reassemble.

PUMP DISASSEMBLY

1. Disconnect power to motor.

2. Disconnect wires to pressure switch.

NOTE: Mark wires for correct
reassembly.

3. Remove pressure switch tube from

barbed fitting on pump body and
allow pump to drain.

4. Remove four capscrews (Ref. No. 17,

Figure 36) and slide motor, seal
plate, impeller, and diffuser (Ref.
Nos. 1, 3, 6 and 7) away from pump
body as a unit.

CLEANING/REPLACING IMPELLER

NOTE: First, follow instructions under
“Pump Disassembly”.

1. Remove diffuser from seal plate

(See Figure 24). Exposed impeller
can now be cleaned.

2. If impeller must be replaced, loosen

two machine screws and remove
motor canopy. If motor has a
capacitor, go to step 3. If motor
does not have a capacitor, go to
step 4.

CAPACITOR VOLTAGE MAY BE
HAZARDOUS. 
To discharge capacitor,
hold insulated handle screwdriver BY
THE HANDLE and short capacitor

terminals together. Do not touch
metal screwdriver blade or capacitor
terminals. If in doubt, consult a
qualified electrician.

3. Unscrew capacitor clamp and

remove capacitor. Do not disconnect
capacitor wires to motor.

4. Slide 7/16” open end wrench in

behind spring loaded switch on
motor end of shaft; hold motor
shaft with wrench on shaft flats and
unscrew impeller by turning
counterclockwise when looking into
eye of impeller (Figures 25 and 26).

5. To reinstall, reverse steps 1 

through 5.

6. See directions under “Pump

Reassembly”, Page 17.

Models 4RJ47, 4RJ48, 4RJ49, 4RJ50, 4P035A and 4P036A

15

Teel Operating Instructions and Parts Manual

®

E

N
G

L

I

S

H

Figure 23 – Pump Disassembly

20

40

60

80

100

Figure 22 – Disconnect Power and Drain
Pump

ON

ON

OFF

OFF

20

40

60

80

100

Figure 24 – Remove Diffuser

Carefully!

A

B

L2

L1

A

B

L2

L1

D

D

7/16"

Figure 25 – Hold Shaft with Wrench

Figure 26 – Unscrew impeller off of
shaft

7/16”

Содержание 4P035A

Страница 1: ...fusers are highly stable high heat thermoplastic Teel convertible jet pump system Model 4RJ49 is a heavy duty convertible jet pump mounted on a 30 gallon horizontal tank Use it on shallow wells up to...

Страница 2: ...motor before connecting to power supply Meet United States National Electri cal Code Canadian Electrical Code and local codes for all wiring Follow wiring instructions in this manual when connecting...

Страница 3: ...20 30 40 50 20 30 40 50 GPH w J32P 24 Venturi 54 Nozzle GPH w J32P 32 Venturi 55 Nozzle GPH w J32P 24 Venturi 54 Nozzle 30 580 420 260 125 900 660 400 140 1070 865 635 385 40 485 325 180 48 720 520 26...

Страница 4: ...0 525 420 320 230 640 565 450 310 80 465 370 285 200 550 470 355 215 GPH w J32P 22 Venturi 53 Nozzle GPH w J32P 22 Venturi 54 Nozzle 90 320 250 190 135 400 345 290 230 100 280 225 170 120 350 300 250...

Страница 5: ...40 385 195 370 325 275 235 60 511 486 378 240 585 420 240 66 340 295 250 210 70 438 408 306 186 305 260 220 180 80 354 330 234 132 275 235 195 155 90 240 200 165 125 100 215 180 145 105 110 165 135 10...

Страница 6: ...n the venturi with the top hole on the front of the pump See Figure 5 NOTE Always replace the ejector when replacing the pump in a shallow well installation 3 Install the pump in the system Make sure...

Страница 7: ...LLATION 2 OR LARGER CASING FIGURE 7 1 Install ejector package 2P429A ejector is included on Model 4RJ49 pump tank system For other heavy duty jet pumps kits are sold separately Follow the instructions...

Страница 8: ...lon tape or a teflon based pipe joint compound on threaded pipe joints Protect the foot valve assembly from fish trash etc by installing a screen around it See Figure 9 4 Lower the pipe into the water...

Страница 9: ...e from the well to the pump Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so that it slopes slightly upward from the well to the pump high spots...

Страница 10: ...n tubing from the pump s AVC port to the port on the AVC mounted on the tank See instructions provided with tank and AVC for details You have just completed the tank connection for your jet pump Pleas...

Страница 11: ...B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connector Type Move black wire from A to L1 1 1 2 2 3 3 230 Volt to 115 Volt Conversion Plug in Type Pull plug straight out from termi...

Страница 12: ...d lead in a service panel to a metal underground water pipe to a metal well casing at least ten feet 3M long or to a ground electrode provided by the power company or the hydro authority 4 Connect the...

Страница 13: ...rder to get all the trapped air out of the piping Don t forget to close the control valve each time before you start the pump 5 When pressure has built up and stabilized at about 50 psi slowly open th...

Страница 14: ...ressure in the system and shut off check the pressure switch operation by opening a faucet or two and running enough water out to bleed off pressure until the pump starts The pump should start when pr...

Страница 15: ...er from seal plate See Figure 24 Exposed impeller can now be cleaned 2 If impeller must be replaced loosen two machine screws and remove motor canopy If motor has a capacitor go to step 3 If motor doe...

Страница 16: ...piping 11 Prime pump as described under Operation REMOVING OLD SEAL 1 Follow instructions under Pump Disassembly 2 Follow steps 1 through 5 under Cleaning Replacing Impeller 3 Remove rotating half of...

Страница 17: ...Operation 4 Check for leaks HELPFUL HINTS HOW TO AVOID OVERPUMPING A SHALLOW WELL In the section on Priming the Shallow Well Pump the instructions were to open the control valve all the way after the...

Страница 18: ...ve assembly L262 4PS L262 4PS L262 5PS L262 5PS L262 5PS 1 12 Pump body L76 48A L76 48A L76 49A L176 40 L176 40 1 13 1 4 NPT Drain plug 1 14 1 8 NPT Pipe plug 1 15 1 4 NPT Barbed fitting st 1 16 Switc...

Страница 19: ...r bushing 1 7 1 NPT Pipe plug 1 8 1 8 NPT Bayonet fitting 1 9 AVC Tube U37 626P 1 10 Air volume control U238 4 1 11 1 4 NPT Bayonet elbow 1 12 1 4 NPT x 11 2 Nipple 1 13 3 8 16 x 11 4 lg Carriage bolt...

Страница 20: ...s on nozzle instead of part number 1 Check valve assembly N212 12P 1 2 1 8 NPT sq hd teflon taped pipe plug 2 3 Ejector body N40 92 1 4 Nozzle 1 each 55 J34P 45 1 51 J34P 41 1 5 Gasket N20 25 1 6 Vent...

Страница 21: ...ler is plugged 3 Clean ejector or impeller see Maintenance 4 Check or foot valves stuck in closed 4 Replace check valve or foot valve position 5 Frozen pipe 5 Thaw pipes Bury pipes below frost line He...

Страница 22: ...m Certain aspects of disclaimers are not applicable to consumer products e g a some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitatio...

Отзывы: