Teel Heavy Duty Cast Iron
Convertible Jet Pumps
Operating Instructions & Parts Manual
4RJ47, 4RJ48, 4RJ49, 4RJ50, 4P035A and 4P036A
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Form 5S3767
®
Description
Teel heavy-duty cast iron convertible jet pumps (Models 4RJ47, 4RJ48, 4RJ50,
4P035A and 4P036A) are adaptable to either shallow or deep well installations. A
shallow well ejector is used for suction lifts of 25 feet or less. It can be used with
drilled (cased) wells, well points, dug wells, and cisterns or lakes. With a deep well
ejector installed, use on wells with 25 to 110 ft. suction lift (depending on ejector
package used). 1/3 HP model is equipped with a split-phase, 115/230 volt dual
voltage motor; 1/2, 3/4, 1, and 1
1
⁄
2
HP models are equipped with capacitor start
115/230 volt dual-voltage motors. All models feature 30-50 psi preset pressure
switch and flow control valve. Impellers and diffusers are highly stable, high heat
thermoplastic.
Teel convertible jet pump system (Model 4RJ49) is a heavy-duty convertible jet
pump mounted on a 30 gallon horizontal tank. Use it on shallow wells (up to 25 ft.
suction lift) as shipped. Can be used with drilled (cased) wells, well points, dug
wells, and cisterns or lakes. With a deep well ejector installed, use on wells with
25-80 ft. suction lift. System is equipped with capacitor start 1/2 HP, 115/230V
motor, convertible ejector, built-in check valve, flow control valve, pressure gauge,
a 30-50 psi preset pressure switch, and pressure tank.
E
N
G
L
I
S
H
Printed in U.S.A.
09319
0400/168/E3
4RJ47
1/3
9.4/4.7
115/230 1
60
3450
230V
30-50 psi
1
1
⁄
4
”
1”
12”
9
1
⁄
4
”
13
1
⁄
2
”
37 lbs.
4RJ48
1/2
12.2/6.1
115/230 1
60
3450
230V
30-50
1
1
⁄
4
1
12
9
1
⁄
4
13
1
⁄
2
36
4RJ49
1/2
12.2/6.1
115/230 1
60
3450
230V
30-50
1
1
⁄
4
1
18
34
45
110
4RJ50
3/4
14.8/7.4
115/230 1
60
3450
230V
30-50
1
1
⁄
4
1
12
9
1
⁄
4
14
1
⁄
2
40
4P035A
1
14.8/7.4
115/230 1
60
3450
230V
30-50
1
1
⁄
4
1
12
9
1
⁄
4
14
1
⁄
2
70
4P036A
1
1
⁄
2
19.2/9.6
115/230 1
60
3450
230V
30-50
1
1
⁄
4
1
12
9
1
⁄
4
15
1
⁄
2
75
Specifications
Motor
Motor
Press.
Inches N.P.T.
Max Load
Conn.
Switch
Suc.
Dis.
Dimensions
Model
HP
Amps
Volts
PH
HZ
RPM
for
Sett.
Inlt
Out
H
W
L
Wt
Unpacking
Open carton and remove unit. Check for
loose, missing, or damaged parts.
See Parts List.
20
40
60
80
100
3688 0400
3689 0400
20
40
60
80
100
20
40
60
80
100
3690 0400
Figure 1