Incorrect e-ChemSaver Flow
While controlling the flow nozzle by nozzle, one of them or a section is not spraying the exact amount of volume per time. Probable causes and
solutions.
Ensure that the flow is adequate to the nozzle within the legislation setting the system to a 100% duty cycle.
•
Set the system up to a 100% duty cycle
If the problem persists (taking account a +/-5%cv) the e-ChemSaver can cause the problem by itself
•
The cylinder holes are blocked. Proceed as explained previously.
•
The plunger’s gasket is broken or damaged. Replace the kit as explained previously.
•
Electrical current is not enough. Usually system’s voltage should be between 11 and 14V. Out of this Interval, an alarm will be shown in
the screen.
Other Relevant Infomation
Issue/Problem
Solution
Example
Can I clean it with high
pressure water?
It is possible. Try not to aim insisting
on the e-ChemSavers for too long
time, particularly to the electrical
connector.
English-International
www.teejet.com
© TeeJet Technologies 2020