MAINTENANCE INSTRUCTIONS 

 

98-01580-EN-R0_A4LT-E-ChemSaver-MaintenanceInstructions-TB.docx 

SOLENOID DISASSEMBLY AND REASSEMBLY 

NOTE: O-rings 

(6, 8, 9)

 should be handled with care as they can be 

damaged/deformed. 

Disassembly 

1.

 

Loosen and remove the nylon Nut 

(1)

2.

 

Separate the Coil Assembly 

(2)

 from the rest of the 

Tube/Plunger Assembly

 (3-10)

3.

 

Remove the Locking Ring 

(10)

4.

 

Using e-ChemSaver (CP116231-NYB) wrench or pliers to grip 

the stainless steel Interface Cap 

(7)

, loosen the Tube Sub-

Assembly 

(3)

 using a 14 mm / 9/16" or adjustable wrench.  

All repairable parts should be accessible at this point. The Plunger 
Sub-Assembly 

(4)

, stainless steel Spring 

(5)

, and O-rings 

(6, 8, 9)

 

can be replaced without further disassembly. 

Reassembly 

5.

 

During reassembly, place the Plunger Sub-Assembly 

(4)

 and 

stainless steel Spring 

(5)

 in the Tube Sub-Assembly 

(3)

NOTE: The Plunger Sub-Assembly 

(4)

 should be orientated with 

the black insert facing outward (visible) when placed in 
the Tube Sub-Assembly 

(3)

6.

 

While compressing the Spring 

(5)

, thread the Tube/Plunger 

Assembly 

(3-10)

 to the stainless steel Interface Cap 

(7)

 and 

tighten using a wrench and pliers. 

 

Optional: Apply 1 drop of Loctite Blue 243 to the threads 

of the Interface Cap 

(7)

 and Tube Sub-Assembly 

(3)

 

Torque Specifications: Tighten Interface Cap 

(7)

 and 

Tube Sub-Assembly 

(3)

 to 1.36 N-m / 12 in-lbs. 

7.

 

Return the Locking Ring 

(10)

 to its original position and slide the 

Tube/Plunger Assembly 

(3-10)

 through the Coil Assembly 

(2)

NOTE: The Coil Assembly 

(2) 

should be orientated with the 

SuperSeal 1.5 connector facing away from the Interface 
Cap 

(7)

8.

 

Tighten the nylon Nut 

(1)

 to the Tube/Plunger Assembly 

(3-10)

Verification After Reassembly 

9.

 

Lubricate O-ring 

(9)

 before re-attaching the e-ChemSaver to the 

nozzle body.

 

10.

 

Attach the solenoid on the nozzle body and inspect for leaks 
when system is on. 

RECOMMENDED: At the time of installation, prior to plugging in the 

connector, spray a sufficient quantity of CorrosionX

®

CorrosionX

®

 Heavy Duty, or CorrosionX

®

 Aviation corrosion 

prevention compound into the connector to wet the 
terminals. 

 

e-ChemSaver Models 

If, for any reason, the change of the complete e-ChemSaver is 
mandatory, there exist 3 different models. For choosing the right one, 
refer to the interface cap (7) indicating the number of different points 
marked on it. 

 

1 MARK

 – Reference 115880-1-12. 

 

2 MARKS

 – Reference 115880-2-12. 

(above image)

 

 

4 MARKS 

– Reference 115880-4-12. 

Figure 1:

 

Model Markings 

 

Содержание e-ChemSaver 115880

Страница 1: ...by using anti corrosion products or small form of silicone at each connection especially the solenoid connections Strainers Remove and clean all the product strainers Replace the strainers after they are clean and dry System Flush 1 Fill the product tank with at least 200 gallons 750 liters of clean water 2 If the boom tubes have a flush valve at the end open the flush valves and flush the boom tu...

Страница 2: ...e ChemSaver is required for optimal functionality and proper operation under any circumstances External Inspection The following parts should be visually inspected before each use Inspection Area Procedure Example Gasket Seal The correct gasket seal ensures a proper connection of the cable In case of difficulty when connecting the cable apply special grease to ensure a proper connection Gasket OK ...

Страница 3: ...ernal body was present in the stainless steel tube clean using dry forced air Clean and Proper Dirty O Ring 9 Observe that the O ring is well well maintained In case of degradation replace it Proper O Ring O Ring 8 Observe that the O ring is well well maintained In case of degradation replace it Interface Cap 7 Clean using clear water Do not use any tool In case of need a paintbrush can be use as ...

Страница 4: ...t the Tube Sub Assembly 4 Replace the tube assembly if the rubber seal is worn or damaged Before After Brown O Ring 6 Observe that the O ring is well well maintained In case of degradation replace it Proper O Ring Stainless Steel Spring 5 Inspect Replace if necessary Plunger 4 gasket If a severe degradation replace the complete kit Reference AB115880 2 KIT Gasket OK Gasket Not OK ...

Страница 5: ...rench and pliers Optional Apply 1 drop of Loctite Blue 243 to the threads of the Interface Cap 7 and Tube Sub Assembly 3 Torque Specifications Tighten Interface Cap 7 and Tube Sub Assembly 3 to 1 36 N m 12 in lbs 7 Return the Locking Ring 10 to its original position and slide the Tube Plunger Assembly 3 10 through the Coil Assembly 2 NOTE The Coil Assembly 2 should be orientated with the SuperSeal...

Страница 6: ...nozzles are still leaking Issue Problem Solution Example Plunger s gasket damaged Change the kit plunger gasket Reference AB115880 2 KIT Solid particles present in the gasket Remove any solid particle present Clean smoothly with pressurized air Sand Dust Blocking the Closure Metal Chip Inserted In The Gasket Stuck plunger in the cylinder due to solid liquid particles Clean with water Stucked Plung...

Страница 7: ...n Example Blocked dirty or stuck nozzle Clean the nozzle with water Damaged electrical connector Change the coil Reference CP115881 12 Broken or defective coil pulse is not heard or detected Change the coil Reference CP115881 12 Stuck e ChemSaver Disassemble the e ChemSaver and clean all the holes with clean water Spray pressure over max working pressure Lower the working pressure the e ChemSaver ...

Страница 8: ...em persists taking account a 5 cv the e ChemSaver can cause the problem by itself The cylinder holes are blocked Proceed as explained previously The plunger s gasket is broken or damaged Replace the kit as explained previously Electrical current is not enough Usually system s voltage should be between 11 and 14V Out of this Interval an alarm will be shown in the screen Other Relevant Infomation Is...

Отзывы: